Version:
Operating temperature / connection cable: -50 ... +200 °C / silicone, measuring insert: 1 x temperature sensor Pt 100 in three-wire circuit, installation length: 250 mm
Screw-in resistance thermometer with connecting cable with fixed screw connectionType: 902050/10-380-1001-1-6-250-104-11-2500/316Silicone connecting cables
Temperature range from -50 to +200 °C
With fixed screw connection
Single resistance thermometer
1x Pt 100 in three-wire circuit
Tolerance class according to DIN EN 60 751: Class B (standard)
Thermowell diameter: 6 mm
Installation length 250 mm
Process connection: G1/2 screw connection
Connection cable end: Wire end ferrules to DIN 46 228 Part 4 (standard)
Connection cable length: 2500 mm
The screw-in resistance thermometer with connection cable is specially designed for use in various industries such as air conditioning and refrigeration technology, heating, furnace and apparatus engineering. It offers precise temperature measurement in both liquid and gaseous media.
The installation design of this thermometer ensures reliable tightness, even under extreme conditions of negative and positive pressure. The possible applications range from dry to humid environments and, depending on the version, enable precise temperature measurement in the range from -50 to +400 °C.
The connection cable of this screw-in resistance thermometer is available in various materials, including PVC, silicone, PTFE and metal braiding. This variety makes it possible to select the right variant for your application. The transition of the connecting cable is strain-relieved and an optional bend protection can be fitted to ensure the longevity of the connection.
The measuring insert is equipped as standard with a Pt 100 temperature insert in accordance with DIN EN 60 751, class B in a two-wire circuit. Optionally, the measuring insert can also be selected with Pt 500 or Pt 1000.
In addition, the connection can be made in either three- or four-wire circuits to meet individual requirements.
Version:
Operating temperature / connection cable: -50 ... +260 °C / PTFE, measuring insert: 1 x Pt 100 temperature sensor in two-wire circuit
Contact resistance thermometer with mounting hole Protective fitting aluminium
Typ: 902550/10-386-1003-1-11-2500/000
Temperature range from -50 to +260°C (PTFE)
1× Pt100 in two-wire circuit
Tolerance class according to DIN EN 60751: Class B (standard)
Connection cable end: Wire end ferrules to DIN 46228 Part 4 (standard)
Connection length in mm: 2500 mm
Extra code: without
Suitable for round and flat surfaces
Quick and uncomplicated installation
with protective fittings made of various materials
Low thermal mass
Optimum heat transfer from the measuring point to the sensor
Contact resistance thermometers are ideal for precise temperature measurements on closed pipe systems and other round or flat surfaces. The uncomplicated mounting with tensioning straps or hose clamps eliminates the need for mechanical processing of the measuring point. Indirect temperature measurement guarantees interference-free temperature measurement, unaffected by flow, pressure or chemical influences. Due to the low thermal mass of the measurement object, the influence is kept to a minimum. Heat-conducting paste is available as an option to optimise heat transfer. Large temperature differences between the measured medium and the environment are directly reflected in the measurement; additional insulation is recommended here. A Pt100 temperature sensor in accordance with DIN EN 60751 Class B is installed as standard in a two-wire circuit, but variants with Pt500, Pt1000 are also possible.
Version:
Operating temperature / connection cable: -50 ... +260 °C / PTFE, measuring insert: 1 x Pt 100 temperature sensor in two-wire circuit
Contact resistance thermometer with mounting hole Stainless steel protective fitting
Typ: 902550/11-386-1003-1-11-2500/000
Temperature range from -50 to +260°C (PTFE)
1× Pt100 in two-wire circuit
Tolerance class according to DIN EN 60751: Class B (standard)
Connection cable end: Wire end ferrules to DIN 46228 Part 4 (standard)
Connection length in mm: 2500 mm
Extra code: without
Suitable for round and flat surfaces
Quick and uncomplicated installation
with protective fittings made of various materials
Low thermal mass
Optimum heat transfer from the measuring point to the sensor
Contact resistance thermometers are ideal for precise temperature measurements on closed pipe systems and other round or flat surfaces. The uncomplicated mounting with tensioning straps or hose clamps eliminates the need for mechanical processing of the measuring point. Indirect temperature measurement guarantees interference-free temperature measurement, unaffected by flow, pressure or chemical influences. Due to the low thermal mass of the measurement object, the influence is kept to a minimum. Heat-conducting paste is available as an option to optimise heat transfer. Large temperature differences between the measured medium and the environment are directly reflected in the measurement; additional insulation is recommended here. A Pt100 temperature sensor in accordance with DIN EN 60751 Class B is installed as standard in a two-wire circuit, but variants with Pt500, Pt1000 are also possible.
Version:
Operating temperature / connection cable: -50 ... +180 °C / silicone, measuring insert: 1 x Pt 100 temperature sensor in two-wire circuit
Contact resistance thermometer with mounting hole Stainless steel protective fitting
Typ: 902550/30-378-1003-1-11-2500/315,
Temperature range from -50 to +260°C (PTFE)
1× Pt100 in two-wire circuit
Tolerance class according to DIN EN 60751: Class B (standard)
Connection cable end: Wire end ferrules to DIN 46228 Part 4 (standard)
Connection length in mm: 2500 mm
Extra code: Spring bend protection
Suitable for round and flat surfaces
Quick and uncomplicated installation
with protective fittings made of various materials
Low thermal mass
Optimum heat transfer from the measuring point to the sensor
Contact resistance thermometers are ideal for precise temperature measurements on closed pipe systems and other round or flat surfaces. The uncomplicated mounting with clamping straps or hose clamps eliminates the need for mechanical processing of the measuring point.Indirect temperature measurement guarantees interference-free temperature measurement, unaffected by flow, pressure or chemical influences. Due to the low thermal mass of the measurement object, the influence is kept to a minimum. Heat-conducting paste is optionally available to optimise heat transfer.Large temperature differences between the measured medium and the environment are directly reflected in the measurement; additional insulation is recommended here.A Pt100 temperature sensor in accordance with DIN EN 6
Version:
Operating temperature / connection cable: -5 ... +105 °C / PVC, measuring insert: 1 x Pt 100 temperature sensor in two-wire circuit
Contact resistance thermometer with mounting hole Protective fitting aluminium
Typ: 902550/31-730-1003-1-11-2500/000
Temperature range from -5 to +105°C (PVC)
1× Pt100 in two-wire circuit
Tolerance class according to DIN EN 60751: Class B (standard)
Connection cable end: Wire end ferrules to DIN 46228 Part 4 (standard)
Connection length in mm: 2500 mm
Extra code: without
Suitable for round and flat surfaces
Quick and uncomplicated installation
with protective fittings made of various materials
Low thermal mass
Optimum heat transfer from the measuring point to the sensor
Contact resistance thermometers are ideal for precise temperature measurements on closed pipe systems and other round or flat surfaces. The uncomplicated mounting with clamping straps or hose clamps eliminates the need for mechanical processing of the measuring point.Indirect temperature measurement guarantees interference-free temperature measurement, unaffected by flow, pressure or chemical influences. Due to the low thermal mass of the measurement object, the influence is kept to a minimum. Heat-conducting paste is optionally available to optimise heat transfer.Large temperature differences between the measured medium and the environment are directly reflected in the measurement; additional insulation is recommended here.A Pt100 temperature sensor in accordance with DIN EN 60751 Class B in a two-wire circuit is fitted as standard, but variants with Pt500, Pt1000 are also possible.
Version:
Operating temperature / connection cable: -50 ... +180 °C / silicone, measuring insert: 1 x Pt 100 temperature sensor in two-wire circuit
Contact resistance thermometer with mounting hole Protective fitting aluminium (D 10x26 mm)
Typ: 902550/31-378-1003-1-11-2500/000
Temperature range from -50 to +180°C (Silicon)
1× Pt100 in two-wire circuit
Tolerance class according to DIN EN 60751: Class B (standard)
Connection cable end: Wire end ferrules to DIN 46228 Part 4 (standard)
Connection length in mm: 2500 mm
Extra code: without
Suitable for round and flat surfaces
Quick and uncomplicated installation
with protective fittings made of various materials
Low thermal mass
Optimum heat transfer from the measuring point to the sensor
Contact resistance thermometers are ideal for precise temperature measurements on closed pipe systems and other round or flat surfaces. The uncomplicated mounting with clamping straps or hose clamps eliminates the need for mechanical processing of the measuring point.Indirect temperature measurement guarantees interference-free temperature measurement, unaffected by flow, pressure or chemical influences. Due to the low thermal mass of the measurement object, the influence is kept to a minimum. Heat-conducting paste is optionally available to optimise heat transfer.Large temperature differences between the measured medium and the environment are directly reflected in the measurement; additional insulation is recommended here.A Pt100 temperature sensor in accordance with DIN EN 60751 Class B in a two-wire circuit is fitted as standard, but variants with Pt500, Pt1000 are also possible.
Version:
Operating temperature / connection cable: -50 ... +180 °C / silicone, measuring insert: 1 x temperature sensor Pt 1000 in two-wire circuit
Contact resistance thermometer with mounting hole Protective fitting aluminium
Typ: 902550/31-378-1005-1-11-2500/000
Temperature range from -50 to +180°C (PVC)
1× Pt1000 in two-wire circuit
Tolerance class according to DIN EN 60751: Class B (standard)
Connection cable end: Wire end ferrules to DIN 46228 Part 4 (standard)
Connection length in mm: 2500 mm
Extra code: without
Suitable for round and flat surfaces
Quick and uncomplicated installation
with protective fittings made of various materials
Low thermal mass
Optimum heat transfer from the measuring point to the sensor
Contact resistance thermometers are ideal for precise temperature measurements on closed pipe systems and other round or flat surfaces. The uncomplicated mounting with clamping straps or hose clamps eliminates the need for mechanical processing of the measuring point.Indirect temperature measurement guarantees interference-free temperature measurement, unaffected by flow, pressure or chemical influences. Due to the low thermal mass of the measurement object, the influence is kept to a minimum. Heat-conducting paste is optionally available to optimise heat transfer.Large temperature differences between the measured medium and the environment are directly reflected in the measurement; additional insulation is recommended here.A Pt100 temperature sensor in accordance with DIN EN 60751 Class B in a two-wire circuit is fitted as standard, but variants with Pt500, Pt1000 are also possible.
Version:
Operating temperature / connection cable: -50 ... +260 °C / PTFE, measuring insert: 1 x Pt 100 temperature sensor in two-wire circuit
Contact resistance thermometer with mounting hole Protective fitting stainless stell
Typ: 902550/20-386-1003-1-11-2500/000
Temperature range from -50 to +260°C (PTFE)
1× Pt100 in two-wire circuit
Tolerance class according to DIN EN 60751: Class B (standard)
Connection cable end: Wire end ferrules to DIN 46228 Part 4 (standard)
Connection length in mm: 2500 mm
Extra code: without
Suitable for round and flat surfaces
Quick and uncomplicated installation
with protective fittings made of various materials
Low thermal mass
Optimum heat transfer from the measuring point to the sensor
Contact resistance thermometers are ideal for precise temperature measurements on closed pipe systems and other round or flat surfaces. The uncomplicated installation with tensioning straps or hose clamps eliminates the need for mechanical processing of the measuring point.Indirect temperature measurement guarantees interference-free temperature measurement, unaffected by flow, pressure or chemical influences. Due to the low thermal mass of the measurement object, the influence is kept to a minimum. Heat-conducting paste is optionally available to optimise heat transfer.Large temperature differences between the measured medium and the environment are directly reflected in the measurement; additional insulation is recommended here.A Pt100 temperature sensor in accordance with DIN EN 60751 Class B in a two-wire circuit is fitted as standard, but variants with Pt500, Pt1000 are also possible.
JUMO hydro TRANS S20 - Humidity and temperature transmitter with optional wall-mounted CO2 module
Typ: 907042/11-0-15-009/000
Basic type extension: RH-T
Version: Standard
Measuring range: 0 ... 100 % rH / -40 ... +80°C
Output: 4 ... 20 mA / 0 ... 10 V combi output config.
Extra code: without
Measuring parameters: Temperature, relative humidity, carbon dioxide (CO2) optional
Interfaces: USB, RS485, Sigle Pair Ethernet (SPE)
Robustness
Easy to install
Multi-sensor
Optional plastic sintered filter
The humidity and temperature transducer monitors the quality of the ambient air and can be wall-mounted both indoors and in protected outdoor areas.
Areas of application
Climate monitoring
Ventilation systems
Building management
Storage rooms
Version:
Measuring range(s): 0 ... 100 % rH / -40 ... +80 °C, output: 4 ... 20mA / 0 ... 10V combi output configurable, extra code: with integrated display
JUMO hydro TRANS S20 - Humidity and temperature transmitter with optional wall-mounted CO2 module
Typ: 907042/11-0-15-009/994
Basic type extension: RH-T
Version: Standard
Measuring range: 0 ... 100 % rH / -40 ... +80°C
Output: 4 ... 20 mA / 0 ... 10 V combi output config.
Extra code: with integrated display
Robustness
Easy to install
Multi-sensor
Optional plastic sintered filter
The humidity and temperature transducer monitors the quality of the ambient air and can be wall-mounted both indoors and in protected outdoor areas.
Areas of application
Climate monitoring
Ventilation systems
Building management
Storage rooms
JUMO hydro TRANS S20 - Humidity and temperature transmitter with optional wall-mounted CO2 module
Typ: 907042/11-0-15-530/000
Basic type extension: RH-T
Version: Standard
Measuring range: 0 ... 100 % rH / -40 ... +80°C
Output: RS-485 Modbus
Extra code: without
Measuring parameters: Temperature, relative humidity, carbon dioxide (CO2) optional
Interfaces: USB, RS485, Sigle Pair Ethernet (SPE)
Robustness
Easy to install
Multi-sensor
Optional plastic sintered filter
The humidity and temperature transducer monitors the quality of the ambient air and can be wall-mounted both indoors and in protected outdoor areas.
Areas of application
Climate monitoring
Ventilation systems
Building management
Storage rooms
Version:
Measuring range(s): 0 ... 95 % rH / -10 ... +60 °C / 10,000 ppm, output: SPE with PoDL (Modbus TCP slave), extra code: with integrated display
JUMO hydro TRANS S20 - Humidity and temperature transmitter with optional wall-mounted CO2 module
Typ: 907042/12-0-17-535/994
Basic type extension: RH-T-CO2
Version: Standard
Measuring range: 0 ... 95 % rH / -10 ... +60°C / 10.000 ppm
Output: SPE with PoDL (modbus TCP slave)
Extra code: Integrated display
Measuring parameters: Temperature, relative humidity, carbon dioxide (CO2) optional
Interfaces: USB, RS485, Sigle Pair Ethernet (SPE)
Robustness
Easy to install
Multi-sensor
Optional plastic sintered filter
The humidity and temperature transducer monitors the quality of the ambient air and can be wall-mounted both indoors and in protected outdoor areas.
Areas of application
Climate monitoring
Ventilation systems
Building management
Storage rooms
Version:
Measuring range(s): 0 ... 100 % rH / -40 ... +80 °C, output: RS-485 Modbus, extra code: with integrated display
JUMO hydro TRANS S20 - Humidity and temperature transmitter with optional wall-mounted CO2 module
Typ: 907042/11-0-15-530/994
Basic type extension: RH-T
Version: Standard
Measuring range: 0 ... 100 % rH / -40 ... +80°C
Output: RS-485 Modbus
Extra code: Integrated display
Measuring parameters: Temperature, relative humidity, carbon dioxide (CO2) optional
Interfaces: USB, RS485, Sigle Pair Ethernet (SPE)
Robustness
Easy to install
Multi-sensor
Optional plastic sintered filter
The humidity and temperature transducer monitors the quality of the ambient air and can be wall-mounted both indoors and in protected outdoor areas.
Areas of application
Climate monitoring
Ventilation systems
Building management
Storage rooms
JUMO hydro TRANS S20 - Humidity and temperature transmitter with optional wall-mounted CO2 module
Typ: 907042/12-0-17-009/000
Basic type extension: RH-T-CO2
Version: Standard
Measuring range: 0 ... 95 % rH / -10 ... +60°C / 10.000 ppm
Output: 4 bis 20 mA / 0 bis 10 V combi output configurable
Extra code: without
Measuring parameters: Temperature, relative humidity, carbon dioxide (CO2) optional
Interfaces: USB, RS485, Sigle Pair Ethernet (SPE)
Robustness
Easy to install
Multi-sensor
Optional plastic sintered filter
The humidity and temperature transducer monitors the quality of the ambient air and can be wall-mounted both indoors and in protected outdoor areas.
Areas of application
Climate monitoring
Ventilation systems
Building management
Storage rooms
JUMO hydro TRANS S20 - Humidity and temperature transmitter with optional wall-mounted CO2 module
Typ: 907042/12-0-17-009/994
Basic type extension: RH-T-CO2
Version: Standard
Measuring range: 0 ... 95 % rH / -10 ... +60°C / 10.000 ppm
Output: 4 ... 20 mA / 0 ... 10 V combi output config.
Extra code: Integrated display
Measuring parameters: Temperature, relative humidity, carbon dioxide (CO2) optional
Interfaces: USB, RS485, Sigle Pair Ethernet (SPE)
Robustness
Easy to install
Multi-sensor
Optional plastic sintered filter
The humidity and temperature transducer monitors the quality of the ambient air and can be wall-mounted both indoors and in protected outdoor areas.
Areas of application
Climate monitoring
Ventilation systems
Building management
Storage rooms
JUMO hydro TRANS S20 - Humidity and temperature transmitter with optional wall-mounted CO2 module
Typ: 907042/12-0-17-530/000
Basic type extension: RH-T-CO2
Version: Standard
Measuring range: 0 ... 95 % rH / -10 ... +60°C / 10.000 ppm
Output: RS-485 Modbus
Extra code: without
Measuring parameters: Temperature, relative humidity, carbon dioxide (CO2) optional
Interfaces: USB, RS485, Sigle Pair Ethernet (SPE)
Robustness
Easy to install
Multi-sensor
Optional plastic sintered filter
The humidity and temperature transducer monitors the quality of the ambient air and can be wall-mounted both indoors and in protected outdoor areas.
Areas of application
Climate monitoring
Ventilation systems
Building management
Storage rooms
Version:
Measuring range(s): 0 ... 95 % rH / -10 ... +60 °C / 10,000 ppm, output: RS-485 Modbus, extra code: with integrated display
JUMO hydro TRANS S20 - Humidity and temperature transmitter with optional wall-mounted CO2 module
Typ: 907042/12-0-17-530/994
Basic type extension: RH-T-CO2
Version: Standard
Measuring range: 0 ... 95 % rH / -10 ... +60°C / 10.000 ppm
Output: RS-485 Modbus
Extra code: Integrated display
Measuring parameters: Temperature, relative humidity, carbon dioxide (CO2) optional
Interfaces: USB, RS485, Sigle Pair Ethernet (SPE)
Robustness
Easy to install
Multi-sensor
Optional plastic sintered filter
The humidity and temperature transducer monitors the quality of the ambient air and can be wall-mounted both indoors and in protected outdoor areas.
Areas of application
Climate monitoring
Ventilation systems
Building management
Storage rooms
Version:
Measuring range: 0 ... 100 % rH / -40 ... +80 °C, output: 4 to 20 mA / 0 to 10 V combined output configured
JUMO hydro TRANS S30 - Humidity and temperature transmitter with optional CO2 module in duct version
Typ: 907043/11
Basic type extension: RH-T Version: StandardMeasuring range: 0 to 100 % RH/-40 to +80 °COutput: 4 to 20 mA/0 to 10 V combined output configuredExtra code: Without
Measuring parametersTemperatureRelative humidityCarbon dioxide (CO2) optional
InterfacesUSB PORTRS485
Areas of applicationClimate monitoringVentilation systemsBuilding managementStorage roomsRailroad applications according to DIN EN 50155
Special featuresRobustnessEasy to installMultisensorOptional plastic sintered filter
The humidity and temperature transducer monitors the outside air flowing into buildings and production processes. It is suitable for installation in weather-protected ventilation ducts.
JUMO hydro TRANS S30 - Humidity and temperature transmitter with optional CO2 module in duct versionTyp: 907043/11
Basic type extension: RH-T Version: StandardMeasuring range: 0 to 100 % RH/-40 to +80 °COutput: RS485 ModbusExtra code: Without
Measuring parametersTemperatureRelative humidityInterfacesRS485
Areas of applicationClimate monitoringVentilation systemsBuilding managementStorage roomsRailroad applications according to DIN EN 50155
Special featuresRobustnessEasy to installMultisensorOptional plastic sintered filter
The humidity and temperature transducer monitors the outside air flowing into buildings and production processes. It is suitable for installation in weather-protected ventilation ducts.
Version:
Measuring range: 0 ... 95 % rH / -10 ... +60 °C / 10000 ppm, output: 4 to 20 mA / 0 to 10 V Combi output configured
JUMO hydro TRANS S30 - Humidity and temperature transmitter with optional CO2 module in duct version
Typ: 907043/12
Basic type extension: RH-T Version: StandardMeasuring range: 0 to 95 % RH/-10 to +60 °COutput: 4 to 20 mA/0 to 10 V combined output configuredExtra code: Without
Measuring parametersTemperatureRelative humidityCarbon dioxide (CO2) optional
InterfacesUSB PORTRS485
Areas of applicationClimate monitoringVentilation systemsBuilding managementStorage roomsRailroad applications according to DIN EN 50155
Special featuresRobustnessEasy to installMultisensorOptional plastic sintered filter
The humidity and temperature transducer monitors the outside air flowing into buildings and production processes. It is suitable for installation in weather-protected ventilation ducts.
JUMO hydro TRANS S30 - Humidity and temperature transmitter with optional CO2 module in duct versionTyp: 907043/12
Basic type extension: RH-T-CO2Version: StandardMeasuring range: 0 to 95 % RH/-10 to +60 °COutput: RS-485 ModbusExtra code: Without
Measuring parametersTemperatureRelative humidityCarbon dioxide (CO2) optional
InterfacesUSB PORTRS485
Areas of applicationClimate monitoringVentilation systemsBuilding managementStorage roomsRailroad applications according to DIN EN 50155
Special featuresRobustnessEasy to installMultisensorOptional plastic sintered filter
The humidity and temperature transducer monitors the outside air flowing into buildings and production processes. It is suitable for installation in weather-protected ventilation ducts.
Version:
Operating temperature / connection cable: -50 ... +150 °C / PTFE connection cable, measuring insert: 1 x Pt 100 temperature sensor in four-wire circuit, installation length: 100 mm
Push-in resistance thermometer in water vapour-tight designType: 902830/10-370-1011-2-6-100-11-2500/317 Measuring range -50 to +150°C Connection cable: PTFE 1x Pt 100 in four-wire circuit Single resistance thermometer Tolerance class A according to DIN EN 60 751 Thermowell diameter: 6 mm Insertion length: 100 mm Connection cable end: Wire end ferrules to DIN 46 228 Connection cable length: 2500 mm (standard) Extra codes: Shielded connecting cableThe plug-in resistance thermometer in water vapour-tight design is preferably used for temperature measurements in sterilisers. Their specific design allows them to be used in atmospheres containing water vapour and under pressure. Another area of application is in apparatus engineering and laboratory technology. The thermometer can be supplied with a PTFE connection cable, which enables operation in humid rooms in the temperature range from -50 to +150 °C, or alternatively an FEP connection cable is available, which covers temperatures from -70 to +200 °C.The transition of the connection cable is strain-relieved to ensure the longevity of the connection. The measuring insert is equipped as standard with a Pt 100 temperature insert in accordance with DIN EN 60 751, class A in a two-wire circuit. In addition, the connection can optionally be made in three- and four-wire circuits to meet individual requirements.
Version:
Operating temperature / connection cable: -50 ... +150 °C / PTFE connection cable, measuring insert: 2 x temperature sensor Pt 100 in three-wire circuit, installation length: 100 mm
Push-in resistance thermometer in water vapour-tight designType: 902830/10-370-2001-2-6-100-11-2500/000 Measuring range -50 to +150°C Connection cable: PTFE 2x Pt 100 in Three-wire circuit Single resistance thermometer Tolerance class A according to DIN EN 60 751 Thermowell diameter: 6 mm Insertion length: 100 mm Connection cable end: Wire end ferrules to DIN 46 228 Connection cable length: 2500 mm (standard) Extra codes: Shielded connecting cableThe plug-in resistance thermometer in water vapour-tight design is preferably used for temperature measurements in sterilisers. Their specific design allows them to be used in atmospheres containing water vapour and under pressure. Another area of application is in apparatus engineering and laboratory technology. The thermometer can be supplied with a PTFE connection cable, which enables operation in humid rooms in the temperature range from -50 to +150 °C, or alternatively an FEP connection cable is available, which covers temperatures from -70 to +200 °C.The transition of the connection cable is strain-relieved to ensure the longevity of the connection. The measuring insert is equipped as standard with a Pt 100 temperature insert in accordance with DIN EN 60 751, class A in a two-wire circuit. In addition, the connection can optionally be made in three- and four-wire circuits to meet individual requirements.
Version:
Operating temperature / connection cable: -70 ... +200 °C / FEP connection cable, measuring insert: 1 x Pt 100 temperature sensor in four-wire circuit, installation length: 50 mm
Push-in resistance thermometer in water vapour-tight design, pressure-tight up to 5.0 barType: 902830/30-302-1011-2-4-50-11-2500/000
Measuring range -70 to +200°C Connection cable: FEP 1 x Pt 100 in four-wire circuit Single resistance thermometer Tolerance class A according to DIN EN 60 751 Thermowell diameter: 4 mm Insertion length: 50 mm Connection cable end: Wire end ferrules to DIN 46 228 Connection cable length: 2500 mm (standard) Extra codes: without extra codeThe insertion resistance thermometer in water vapour-tight design is preferably used for temperature measurements in sterilisers. Their specific design allows them to be used in atmospheres containing water vapour and under pressure. Another area of application is in apparatus engineering and laboratory technology. The thermometer can be supplied with a PTFE connection cable, which enables operation in humid rooms in the temperature range from -50 to +150 °C, or alternatively an FEP connection cable is available, which covers temperatures from -70 to +200 °C.The transition of the connection cable is strain-relieved to ensure the longevity of the connection. The measuring insert is equipped as standard with a Pt 100 temperature insert in accordance with DIN EN 60 751, class A in a two-wire circuit. In addition, the connection can optionally be made in three- and four-wire circuits to meet individual requirements.