Diaphragm:
PTFE - ring
|
Electrical connection of the electrode (onto which the cable is plugged):
Screw head Pg13.5 (S8)
|
Measuring resistor (temperature sensor):
without
The JUMO "Heavy Duty" pH electrode records the pH value of water and aqueous media. The rugged industrial electrode is designed for the most demanding applications with increased dirt and toxic loads as well as oily media.Advantages:stable and reliable measured values
low maintenance and robustextended service lifeSelected version:without temperature sensorS8 N-srew head Pg13,5, PPS
materialPTFE ring diaphragmInsertion length 120mm (standard)Type code (can also be found on your electrode): 201021/10-12-04-18-120/841Features: for industrial applications; also in heavy-duty and hygienic version for demanding processes; integrated temperature sensorApplication range: process measurement; high temperature applications; suspensions; electroplating; lacquers; waste water; ultrapure water; water; always contaminated media; hygienic and sterile applications; boiler feed water If you require other versions of this electrode, please use our configurator and configure the suitable electrode for you. You can download the JUMO data sheet just below our text. You will find our configurator on page 6 of the data sheet. Please note that the delivery time for freely configured electrodes is 5 to 6 weeks.
Diaphragm:
Hole diaphragm
|
Electrical connection of the electrode (onto which the cable is plugged):
VarioPin (VP) plug-in head Pg13.5
|
Measuring resistor (temperature sensor):
PT1000
The JUMO "Heavy Duty" pH electrode records the pH value of water and aqueous media. The rugged industrial electrode is designed for the most demanding applications with increased dirt and toxic loads as well as oily media.Advantages:stable and reliable measured values
low maintenance and robustextended service lifeSelected version:PT1000 temperature sensorVarioPin electrode head (always required for versions with temperature sensor)Hole diaphragmInsertion length 120mm (standard)Type code (can also be found on your electrode): 201021/10-12-11-18-120/841Features: for industrial applications; also in heavy-duty and hygienic version for demanding processes; integrated temperature sensorApplication range: process measurement; high temperature applications; suspensions; electroplating; lacquers; waste water; ultrapure water; water; always contaminated media; hygienic and sterile applications; boiler feed water If you require other versions of this electrode, please use our configurator and configure the suitable electrode for you. You can download the JUMO data sheet just below our text. You will find our configurator on page 6 of the data sheet. Please note that the delivery time for freely configured electrodes is 5 to 6 weeks.
Diaphragm:
PTFE - ring
|
Electrical connection of the electrode (onto which the cable is plugged):
VarioPin (VP) plug-in head Pg13.5
|
Measuring resistor (temperature sensor):
PT100
The JUMO "Heavy Duty" pH electrode records the pH value of water and aqueous media. The rugged industrial electrode is designed for the most demanding applications with increased dirt and toxic loads as well as oily media.Advantages:stable and reliable measured values
low maintenance and robustextended service lifeSelected version:PT100 temperature sensorVarioPin electrode head (always required for versions with temperature sensor)PTFE ring diaphragmInsertion length 120mm (standard)Type code (can also be found on your electrode): 201021/10-12-04-18-120/840Features: for industrial applications; also in heavy-duty and hygienic version for demanding processes; integrated temperature sensorApplication range: process measurement; high temperature applications; suspensions; electroplating; lacquers; waste water; ultrapure water; water; always contaminated media; hygienic and sterile applications; boiler feed water If you require other versions of this electrode, please use our configurator and configure the suitable electrode for you. You can download the JUMO data sheet just below our text. You will find our configurator on page 6 of the data sheet. Please note that the delivery time for freely configured electrodes is 5 to 6 weeks.
Diaphragm:
PTFE - ring
|
Electrical connection of the electrode (onto which the cable is plugged):
VarioPin (VP) plug-in head Pg13.5
|
Measuring resistor (temperature sensor):
PT1000
The JUMO "Heavy Duty" pH electrode records the pH value of water and aqueous media. The rugged industrial electrode is designed for the most demanding applications with increased dirt and toxic loads as well as oily media.Advantages:stable and reliable measured values
low maintenance and robustextended service lifeSelected version:PT1000 temperature sensorVarioPin electrode head (always required for versions with temperature sensor)PTFE ring diaphragmInsertion length 120mm (standard)Type code (can also be found on your electrode): 201021/10-12-04-18-120/841Features: for industrial applications; also in heavy-duty and hygienic version for demanding processes; integrated temperature sensorApplication range: process measurement; high temperature applications; suspensions; electroplating; lacquers; waste water; ultrapure water; water; always contaminated media; hygienic and sterile applications; boiler feed water If you require other versions of this electrode, please use our configurator and configure the suitable electrode for you. You can download the JUMO data sheet just below our text. You will find our configurator on page 6 of the data sheet. Please note that the delivery time for freely configured electrodes is 5 to 6 weeks.
Active part:
HA glass: pH 0 ... 14; -5 ... +80°C (high alkali use)
|
Basic type supplement:
Glass shaft, cartridge deflection system
|
Diaphragm:
PTFE - ring
|
Electrical connection of the electrode (onto which the cable is plugged):
Screw head Pg13.5 (S8)
|
Extra code:
Salt reservoir (837)
|
Insertion length:
120mm
Typical areas of applicationindustrial waste water technologyprocess measurements, electroplating, paper industry, beverage industryoily waste watersuspensions, lacquers, media with solid particlesDouble-chamber design in the presence of electrode poisonsFluoride-containing (hydrofluoric acid-containing) media up to 1000 mg/l HFSpecial featuresDirt-repellent PTFE ring diaphragm with highly viscous KCl solution (gel) or perforated or annular gap diaphragm with polymerised solid electrolyte - practically blockage-freeCartridge discharge system with silver ion-free reference electrolytePressure-resistant versions up to 10 bar (50 °C)Temperature range: see order detailsOptional temperature sensors can be integratedOptional salt reservoir to increase service life in media with low conductivity
Active part:
UW glass: pH 0 ... 12 (14 for short periods); -5 ... +80°C
|
Basic type supplement:
Glass shaft, cartridge deflection system
|
Diaphragm:
1x zirconium dioxide
|
Electrical connection of the electrode (onto which the cable is plugged):
Screw head Pg13.5 (S8)
|
Extra code:
Salt reservoir (837)
|
Insertion length:
120mm
high-quality industrial electrodesprocess/industrial applicationsadditional integrable temperature sensordifferent insertion lengthsspecial types on request
Active part:
UW glass: pH 0 ... 12 (14 for short periods); -5 ... +80°C
|
Basic type supplement:
Glass shaft, cartridge deflection system
|
Diaphragm:
Ring-gap diaphragm, gel of polymerised solid electrolyte ("diaphragmless")
|
Electrical connection of the electrode (onto which the cable is plugged):
Screw head Pg13.5 (S8)
|
Extra code:
Salt reservoir (837)
|
Insertion length:
120mm
Typical areas of applicationindustrial waste water technologyprocess measurements, electroplating, paper industry, beverage industryoily waste watersuspensions, lacquers, media with solid particlesDouble-chamber design in the presence of electrode poisonsFluoride-containing (hydrofluoric acid-containing) media up to 1000 mg/l HFSpecial featuresDirt-repellent PTFE ring diaphragm with highly viscous KCl solution (gel) or perforated or annular gap diaphragm with polymerised solid electrolyte - practically blockage-freeCartridge discharge system with silver ion-free reference electrolytePressure-resistant versions up to 10 bar (50 °C)Temperature range: see order detailsOptional temperature sensors can be integratedOptional salt reservoir to increase service life in media with low conductivity
Active part:
HA glass: pH 0 ... 14; -5 ... +80°C (high alkali use)
|
Basic type supplement:
Glass shaft, cartridge deflection system
|
Diaphragm:
1x zirconium dioxide
|
Electrical connection of the electrode (onto which the cable is plugged):
Screw head Pg13.5 (S8)
|
Extra code:
Salt reservoir (837)
|
Insertion length:
120mm
high-quality industrial electrodesprocess/industrial applicationsadditional integrable temperature sensordifferent insertion lengthsspecial types on request
Active part:
UW glass: pH 0 ... 12 (14 for short periods); -5 ... +80°C
|
Basic type supplement:
Glass shaft, cartridge deflection system
|
Diaphragm:
PTFE - ring
|
Electrical connection of the electrode (onto which the cable is plugged):
Screw head Pg13.5 (S8)
|
Extra code:
without (000)
|
Insertion length:
120mm
Typical areas of applicationindustrial waste water technologyprocess measurements, electroplating, paper industry, beverage industryoily waste watersuspensions, lacquers, media with solid particlesDouble-chamber design in the presence of electrode poisonsFluoride-containing (hydrofluoric acid-containing) media up to 1000 mg/l HFSpecial featuresDirt-repellent PTFE ring diaphragm with highly viscous KCl solution (gel) or perforated or annular gap diaphragm with polymerised solid electrolyte - practically blockage-freeCartridge discharge system with silver ion-free reference electrolytePressure-resistant versions up to 10 bar (50 °C)Temperature range: see order detailsOptional temperature sensors can be integratedOptional salt reservoir to increase service life in media with low conductivity
Active part:
C-glass, pH 0 ... 12, -5 ... + 50 °C, fluoride-resistant up to 1000 mg HF/l
|
Basic type supplement:
Glass shaft, cartridge deflection system
|
Diaphragm:
1x zirconium dioxide
|
Electrical connection of the electrode (onto which the cable is plugged):
Screw head Pg13.5 (S8)
|
Extra code:
without (000)
|
Insertion length:
120mm
high-quality industrial electrodesprocess/industrial applicationsadditional integrable temperature sensordifferent insertion lengthsspecial types on request
Active part:
UW glass: pH 0 ... 12 (14 for short periods); -5 ... +80°C
|
Basic type supplement:
Glass shaft, cartridge deflection system
|
Diaphragm:
1x zirconium dioxide
|
Electrical connection of the electrode (onto which the cable is plugged):
Screw head Pg13.5 (S8)
|
Extra code:
without (000)
|
Insertion length:
225mm
high-quality industrial electrodesprocess/industrial applicationsadditional integrable temperature sensordifferent insertion lengthsspecial types on request
Active part:
UW glass: pH 0 ... 12 (14 for short periods); -5 ... +80°C
|
Basic type supplement:
Glass shaft, cartridge deflection system
|
Diaphragm:
1x zirconium dioxide
|
Electrical connection of the electrode (onto which the cable is plugged):
Screw head Pg13.5 (S8)
|
Extra code:
without (000)
|
Insertion length:
120mm
high-quality industrial electrodesprocess/industrial applicationsadditional integrable temperature sensordifferent insertion lengthsspecial types on request
Active part:
HT-Glas: pH 0 ... 14; -5 ... +135°C
|
Basic type supplement:
Glass shaft, high-temperature gel, sealed, cartridge discharge system
|
Diaphragm:
1x zirconium dioxide
|
Electrical connection of the electrode (onto which the cable is plugged):
Screw head Pg13.5 (S8)
|
Extra code:
without (000)
|
Insertion length:
120mm
Typical areas of applicationProcesses with higher continuous temperatures (up to a maximum of 135 °C)Sterilisation applicationsDouble chamber design in the presence of electrode poisonsfluoride-containing (hydrofluoric acid-containing) media up to 1000 mg HF/lSpecial featuresproven JUMO HT glass (pH high-temperature membrane glass) 0 ... 14 pHJUMO DS membrane glass for sterilization applicationsCartridge discharge system with silver ion-free reference electrolyte (gel)Pressure-resistant versions up to 10 bar (50 °C)Temperature range: 0 ... 135 °C1Temperature sensors can be integrated as an optionORP versions with platinum or gold cap up to ±2000 mV
Active part:
HT-Glas: pH 0 ... 14; -5 ... +135°C
|
Basic type supplement:
Glass shaft, high-temperature gel, sealed, cartridge discharge system
|
Diaphragm:
Hole diaphragm, gel of polymerised solid electrolyte ("diaphragmless")
|
Electrical connection of the electrode (onto which the cable is plugged):
Screw head Pg13.5 (S8)
|
Extra code:
Salt reservoir (837)
|
Insertion length:
120mm
Typical areas of applicationProcesses with higher continuous temperatures (up to a maximum of 135 °C)Sterilisation applicationsDouble chamber design in the presence of electrode poisonsfluoride-containing (hydrofluoric acid-containing) media up to 1000 mg HF/lSpecial featuresproven JUMO HT glass (pH high-temperature membrane glass) 0 ... 14 pHJUMO DS membrane glass for sterilization applicationsCartridge discharge system with silver ion-free reference electrolyte (gel)Pressure-resistant versions up to 10 bar (50 °C)Temperature range: 0 ... 135 °C1Temperature sensors can be integrated as an optionORP versions with platinum or gold cap up to ±2000 mV
Active part:
HT-Glas: pH 0 ... 14; -5 ... +135°C
|
Basic type supplement:
Glass shaft, high-temperature gel, sealed, cartridge discharge system
|
Diaphragm:
Hole diaphragm, gel of polymerised solid electrolyte ("diaphragmless")
|
Electrical connection of the electrode (onto which the cable is plugged):
VarioPin (VP) plug-in head Pg13.5
|
Extra code:
Salt reserve + with integrated Pt100
|
Insertion length:
120mm
Typical areas of applicationProcesses with higher continuous temperatures (up to a maximum of 135 °C)Sterilisation applicationsDouble chamber design in the presence of electrode poisonsfluoride-containing (hydrofluoric acid-containing) media up to 1000 mg HF/lSpecial featuresproven JUMO HT glass (pH high-temperature membrane glass) 0 ... 14 pHJUMO DS membrane glass for sterilization applicationsCartridge discharge system with silver ion-free reference electrolyte (gel)Pressure-resistant versions up to 10 bar (50 °C)Temperature range: 0 ... 135 °C1Temperature sensors can be integrated as an optionORP versions with platinum or gold cap up to ±2000 mV
Active part:
UW glass: pH 0 ... 12 (14 for short periods); -5 ... +80°C
|
Basic type supplement:
Glass shaft, cartridge deflection system
|
Diaphragm:
Hole diaphragm, gel of polymerised solid electrolyte ("diaphragmless")
|
Electrical connection of the electrode (onto which the cable is plugged):
VarioPin (VP) plug-in head Pg13.5
|
Extra code:
Salt reserve + with integrated Pt100
|
Insertion length:
120mm
Typical areas of applicationindustrial waste water technologyprocess measurements, electroplating, paper industry, beverage industryoily waste watersuspensions, lacquers, media with solid particlesDouble-chamber design in the presence of electrode poisonsFluoride-containing (hydrofluoric acid-containing) media up to 1000 mg/l HFSpecial featuresDirt-repellent PTFE ring diaphragm with highly viscous KCl solution (gel) or perforated or annular gap diaphragm with polymerised solid electrolyte - practically blockage-freeCartridge discharge system with silver ion-free reference electrolytePressure-resistant versions up to 10 bar (50 °C)Temperature range: see order detailsOptional temperature sensors can be integratedOptional salt reservoir to increase service life in media with low conductivity
Active part:
UW glass: pH 0 ... 12 (14 for short periods); -5 ... +80°C
|
Basic type supplement:
Glass shaft, cartridge deflection system
|
Diaphragm:
Hole diaphragm, gel of polymerised solid electrolyte ("diaphragmless")
|
Electrical connection of the electrode (onto which the cable is plugged):
Screw head Pg13.5 (S8)
|
Extra code:
Salt reservoir (837)
|
Insertion length:
120mm
Typical areas of applicationindustrial waste water technologyprocess measurements, electroplating, paper industry, beverage industryoily waste watersuspensions, lacquers, media with solid particlesDouble-chamber design in the presence of electrode poisonsFluoride-containing (hydrofluoric acid-containing) media up to 1000 mg/l HFSpecial featuresDirt-repellent PTFE ring diaphragm with highly viscous KCl solution (gel) or perforated or annular gap diaphragm with polymerised solid electrolyte - practically blockage-freeCartridge discharge system with silver ion-free reference electrolytePressure-resistant versions up to 10 bar (50 °C)Temperature range: see order detailsOptional temperature sensors can be integratedOptional salt reservoir to increase service life in media with low conductivity
Active part:
UW glass: pH 0 ... 12 (14 for short periods); -5 ... +80°C
|
Basic type supplement:
Glass shaft, cartridge deflection system
|
Diaphragm:
PTFE - ring
|
Electrical connection of the electrode (onto which the cable is plugged):
Screw head Pg13.5 (S8)
|
Extra code:
Salt reservoir (837)
|
Insertion length:
225mm
High-quality industrial electrodesprocess/industrial applicationsadditional integrable temperature probedifferent installation lengthsspecial types on request
Active part:
UW glass: pH 0 ... 12 (14 for short periods); -5 ... +80°C
|
Basic type supplement:
Glass shaft, cartridge deflection system
|
Diaphragm:
PTFE - ring
|
Electrical connection of the electrode (onto which the cable is plugged):
Screw head Pg13.5 (S8)
|
Extra code:
without (000)
|
Insertion length:
225mm
Typical areas of applicationindustrial waste water technologyprocess measurements, electroplating, paper industry, beverage industryoily waste watersuspensions, lacquers, media with solid particlesDouble-chamber design in the presence of electrode poisonsFluoride-containing (hydrofluoric acid-containing) media up to 1000 mg/l HFSpecial featuresDirt-repellent PTFE ring diaphragm with highly viscous KCl solution (gel) or perforated or annular gap diaphragm with polymerised solid electrolyte - practically blockage-freeCartridge discharge system with silver ion-free reference electrolytePressure-resistant versions up to 10 bar (50 °C)Temperature range: see order detailsOptional temperature sensors can be integratedOptional salt reservoir to increase service life in media with low conductivity
Active part:
UW glass: pH 0 ... 12 (14 for short periods); -5 ... +80°C
|
Basic type supplement:
Glass shaft, cartridge deflection system
|
Diaphragm:
PTFE - ring
|
Electrical connection of the electrode (onto which the cable is plugged):
VarioPin (VP) plug-in head Pg13.5
|
Extra code:
Temperature sensor Pt100
|
Insertion length:
120mm
Typical areas of applicationindustrial waste water technologyprocess measurements, electroplating, paper industry, beverage industryoily waste watersuspensions, lacquers, media with solid particlesDouble-chamber design in the presence of electrode poisonsFluoride-containing (hydrofluoric acid-containing) media up to 1000 mg/l HFSpecial featuresDirt-repellent PTFE ring diaphragm with highly viscous KCl solution (gel) or perforated or annular gap diaphragm with polymerised solid electrolyte - practically blockage-freeCartridge discharge system with silver ion-free reference electrolytePressure-resistant versions up to 10 bar (50 °C)Temperature range: see order detailsOptional temperature sensors can be integratedOptional salt reservoir to increase service life in media with low conductivity
Active part:
UW glass: pH 0 ... 12 (14 for short periods); -5 ... +80°C
|
Basic type supplement:
Glass shaft, cartridge deflection system
|
Diaphragm:
PTFE - ring
|
Electrical connection of the electrode (onto which the cable is plugged):
VarioPin (VP) plug-in head Pg13.5
|
Extra code:
Salt reserve + with integrated Pt100
|
Insertion length:
120mm
Typical areas of applicationindustrial waste water technologyprocess measurements, electroplating, paper industry, beverage industryoily waste watersuspensions, lacquers, media with solid particlesDouble-chamber design in the presence of electrode poisonsFluoride-containing (hydrofluoric acid-containing) media up to 1000 mg/l HFSpecial featuresDirt-repellent PTFE ring diaphragm with highly viscous KCl solution (gel) or perforated or annular gap diaphragm with polymerised solid electrolyte - practically blockage-freeCartridge discharge system with silver ion-free reference electrolytePressure-resistant versions up to 10 bar (50 °C)Temperature range: see order detailsOptional temperature sensors can be integratedOptional salt reservoir to increase service life in media with low conductivity
Active part:
UW glass: pH 0 ... 12 (14 for short periods); -5 ... +80°C
|
Basic type supplement:
Glass shaft, cartridge deflection system
|
Diaphragm:
1x zirconium dioxide
|
Electrical connection of the electrode (onto which the cable is plugged):
VarioPin (VP) plug-in head Pg13.5
|
Extra code:
Salt reserve + with integrated Pt100
|
Insertion length:
120mm
high-quality industrial electrodesprocess/industrial applicationsadditional integrable temperature sensordifferent insertion lengthsspecial types on request
Active part:
UW glass: pH 0 ... 12 (14 for short periods); -5 ... +80°C
|
Basic type supplement:
PEI plastic shaft with protective cage, glass fibre diaphragm, cartridge discharge system
|
Diaphragm:
1x glass silk
|
Electrical connection of the electrode (onto which the cable is plugged):
Screw head Pg13.5 (S8)
|
Extra code:
Salt storage + double chamber (DOKA) with KCL/KCL bridge
|
Insertion length:
120mm
high-quality industrial electrodesprocess/industrial applicationsadditional integrable temperature sensordifferent insertion lengthsspecial types on request
Active part:
UW glass: pH 0 ... 12 (14 for short periods); -5 ... +80°C
|
Basic type supplement:
Plastic shaft PSU with protective basket, glass silk diaphragm, cartridge discharge system
|
Diaphragm:
1x glass silk
|
Electrical connection of the electrode (onto which the cable is plugged):
Screw head Pg13.5 (S8)
|
Extra code:
without (000)
|
Insertion length:
225mm
high-quality industrial electrodesprocess/industrial applicationsadditional integrable temperature sensordifferent insertion lengthsspecial types on request