JUMO Midas C08 - OEM - Basic pressure transmitter

Typ: 401002/000-462-405-502-20-601-61/000

  •  Input: 0 to 40 bar relative pressure
  •  Output: 4 to 20 mA, two-wire
  •  Process connection: G 1/4 DIN EN 837
  •  Process connection material: CrNi (stainless steel)
  •  Seal material: CrNi (stainless steel)
  •  Electrical connection: Cable socket DIN EN 175301-803, form A
  •  Extra code: none
  •  New quality level especially for the OEM sector
  •  Long-term stability below 0.2%
  •  Temperature compensation range extended by 50% to -20 to +100 °C
  •  Device installation 60% faster thanks to QUICKON quick-clamp technology
  •  Vibration resistance 2.5 times higher than the industry standard
  •  Manufactured in Germany

For applications that require reliable and long-term realisation of measurement tasks, the pressure transmitter from the Midas family is used as a basic product. In addition to the basic product, the Midas family offers solutions for every specific task.
The innovative and patented sensor design of the specially developed ceramic sensor results in excellent long-term stability < 0.2%. The transmitter detects relative pressures from 1.6 to 60 bar in gaseous or liquid media.

Areas of application:

  •  Mechanical and plant engineering
  •  compressors
  •  Building services engineering
  •  Industrial pneumatics
  •  Commercial vehicles

Added value for the customer:

  •  Process reliability: Thanks to design measures, the pressure transmitter has excellent vibration resistance and can be used under high vibration loads, such as those that occur in commercial vehicles. A fully automatic measuring and calibration system, diagnostic function of the circuit and 100% final inspection guarantee the highest quality.
  •  Cost-effectiveness: QUICKON quick-clamp technology enables time-saving and safe installation. The spring contacts ensure reliable contacting even in the event of temperature fluctuations. This electrical connection shortens assembly times and reduces costs by 60% compared to conventional connection variants.
  •  Versatility: The large selection of measuring ranges as well as process and electrical connections enables universal use of the pressure transmitter. 

Dimensions

Height 3,5 cm
Length 16,5 cm
Width 10,5 cm

Weight

Weight 10 g

Other attributes

Country of origin DE
Customs tariff number 90262020
Eingangsdruck 0 bis 40 bar Relativdruck
Prozessanschluss Verschraubung G 1/4
Technical data:

General

Reference conditions

DIN 16086 and DIN EN 60770

Sensor

Measuring principle

Permissible load changes

 

Thick film on ceramic body (piezoresistiv)

> 10 Millionen, 0 until 100 % Measuring range

Mounting position

Calibrationslage

any

Device standing vertically, process connection at the bottom

Measuring range and accuracy

 

Measuring range

Linearity

 

% MSPf

Accuracy at

Long-term stability

% MSP

per annum

Overload capability

bar

Burst pressure

bar

20 °Cd

% MSP

-10 to +85 °Ce

% MSP

-20 to +100 °Ce

% MSP

0 to 1.6 bar relative pressure

0,25

0,5

0,65

1

0,2

6

12

0 to 2.5 bar relative pressure

6

12

0 to 4 bar relative pressure

0,35

0,5

12

25

0 to 6 bar relative pressure

12

25

0 to 10 bar relative pressure

20

38

0 to 16 bar relative pressure

50

75

0 to 25 bar relative pressure

50

75

0 to 40 bar relative pressure

120

200

0 to 60 bar relative pressure

120

200

-1 to +0.6 bar relative pressure

0,5

0,65

6

12

-1 to +1.5 bar relative pressure

6

12

-1 to +3 bar relative pressure

0,35

0,5

12

25

-1 to +5 bar relative pressure

12

25

-1 to +9 bar relative pressure

20

38

-1 to +15 bar relative pressure

50

75

-1 to +24 bar relative pressure

50

75

a Linearity after limit point setting

b  Reference conditions EN 61298-1

c  All pressure transmitters are vacuum-proof.

d Includes: linearity, hysteresis, repeatability, deviation from initial and full scale

e Includes: linearity, hysteresis, repeatability, deviation of initial and full scale range, thermal influence on starting range and span

f  MSP = Span

 

 

 

 

Exit

 

Analog

Other outputs are available on request.

Current

4 to 20 mA, Two-wire

Voltage

DC 0,5 to 4,5 V, Three-wire, ratiometric 10 to 90 % of the power supply

 

DC 0 to 10 V, Three-wire

 

DC 1 bis 5 V, Three-wire

 

DC 1 bis 6 V, Three-wire

Jump Response T90

£ 2 ms

Burde

         Current

         Voltage

         (Load connected against "0 V/S-")

 

RL £ (UB - 8 V) ÷ 0,02 A (W) at 4 to 20 mA, two-wire RL ³ 5 kW at DC 0.5 to 4.5 V, three-wire

RL ³ 10 kW at DC 0 to 10 V, three-wire RL ³ 10 kW at DC 1 to 5 V, three-wire

RL ³ 10 kW at DC 1 to 6 V, three-wire

 

 

 

Mechanical Properties

 

Materials

 

Process connection

Stainless Steel 304

Gasket 600 (internal)

EPDM

Gasket 601 (internal)

FKM, standard

Gasket 602 (internal)

CR

Gasket 604 (internal)

FFKM

Gasket 609 (internal)

NBR

Process connection G 1/4 (externa)

FKM

Sensor

Case

Ceramics Al2O3 96 %

Stainless steel 304

fixed cable

PBT-GF30, PVC

QUICKON

PBT-GF30

Round plug M12 × 1

PBT-GF30, Edelstahl 303 L

Bayonet stecker

PBT-GF30

Electrical connector

PBT-GF30, PA, Silikon

Gewicht

70 g with process connection G 1/4

a  Pay attention to the resistance of the selected sealing material!

 

Environmental impact

 

Medium temperature

with electrical connection

 

fixed cable

-20 to +125 °C

Round plugs M12 × 1

-20 to +125 °C

Bayonet stecker

-20 to +125 °C

Electrical connector

-20 to +125 °C

Ambient temperature

with electrical connection

 

fixed cable

-20 to +100 °C

limited operation at ambient temperature -30 °C; Use only stationary, Kabelbruchgefahr

Round plugs M12 × 1

-20 to +100 °C

Bayonet stecker

-20 to +100 °C

Electrical connector

-20 to +100 °C

Storage temperature

with electrical connection

 

fixed cable

-30 to +100 °C

Round plugs M12 × 1

-40 to +100 °C

Bayonet stecker

-40 to +100 °C

Electrical connector

-40 to +100 °C

zulässige Luftfeuchtigkeit Betrieb

Lagerung

 

100 % relative humidity incl. condensation on the outer shell of the device 90 % relative humidity without condensation

Permissible mechanical stress

Vibration Resistance Shock Resistance

 

50 g at 10 to 2000 Hz, according to IEC 60068-2-6

50 g for 3 ms, 100 g for 2 ms, according to IEC 60068-2-27

electromagnetic compatibility (EMV) Emission

Stability

nach EN 61326-2-3

Class Ba Industrial Requirement

Protection

after EN 60529

for electrical connection

 

fixed cable

IP67

QUICKONb

IP67

Round plugs M12 × 1c

IP67

Baonet steckerc

IP67

Cable boxec, d

IP65

a The product is suitable for industrial use as well as for household and small businesses.

b  Connecting cable diameter minimum 3.5 mm, maximum 6 mm

c  The degree of protection can only be achieved with a suitable, mounted counterpart.

d  Connecting cable diameter minimum 6 mm, maximum 8 mm

 

Electric Dating

 

Power supply UB

Ripple: The voltage peaks must not exceed or fall below the specified values of the power supply!

4 to 20 mA, Two-wire

DC 8 to 30 V, Nominal power supply DC 24 V

DC 0,5 to 4,5 V, Three-wire

DC 3 to 5,25 V, Nominal power supply DC 5 V, ratiometric output 10 to 90 % of the power supply

DC 0 to 10 V, Three-wire

DC 11,5 to 30 V, Nominal power supply DC 24 V

DC 1 to 5 V, Three-wire

DC 8 to 30 V, Nominal power supply DC 24 V

DC 1 to 6 V, Three-wire

DC 8 to 30 V, Nominal power supply DC 24 V

Current consumption incl. load

 

£ 25 mA

£ 3 mA

£ 3 mA

£ 3 mA

£ 3 mA

4 to 20 mA, Two-wire

DC 0,5 to 4,5 V, Three-wire

DC 0 to 10 V, Three-wire

DC 1 to 5 V, Three-wire

DC 1 to 6 V, Three-wire

Reverse polarity protection

yes

Circuit Requirement

SELV

The device must be supplied with an electrical circuit that meets the requirements for "energy-limited circuits" of EN 61010-1.

 

Approvals and test marks

 

EAC

Testing Laboratory Certificates/Inspection Numbers Test Basis

applies to:

 

«Промтехконтроль»

ЕАЭС N RU Д-DE.PA01.В.80830/21 TR TS 020/2011

Typ 401002

UL

 

Checkpoint

Underwriter Laboratories

Certificates/Verification Numbers

E201387

Test basis

UL 61010-1 (3. Ed.), CAN/CSA-22.2 No. 61010-1 (3. Ed.)

applies to:

Type Suffix 061