Product information "JUMO miroVIEW mit 2 Relais, 76 x 36 x 62 mm"
JUMO miro VIEW - smart digital indicator with limit value monitoring
Typ: 701580/0-01-23-02
- Input: 1 resistance thermometer Pt100, Pt1000 in two-wire circuit, 1 digital input
- Output: 1 relay (changeover contact AC 250 V, 10 A) and 1 relay (make contact AC 250 V, 5 A) resistive load
- Power supply: AC 230 V +10/-15 %, 48 to 63 Hz
The smart digital indicator is used to electronically display various process variables.
The device records the process variables via resistance thermometer, thermocouple, current 0(4) to 20 mA or voltage 0 to 10 V. Other functions include limit value monitoring, min/max value storage, hold function and tare function. The device can be supplied either with 2 relays or with 1 relay and 1 digital output (DC0/14 V). It is characterised by user-friendly, clear operation in German, English, French and Spanish.
Process values, texts and parameters are displayed on two 18-segment LCD displays. Additional display elements provide information about
- Switching positions of the outputs
- Status of the timer
- Temperature unit
PCB terminals with push-in technology enable quick electrical installation. Operation, parameterisation and configuration are carried out via a membrane keypad with four buttons.
Display function
In addition to the conventional display of the measured value, the device offers additional functions such as
- Display of min/max values
- Hold function to hold the current measured value
- Tare function for weighing applications
Some of these functions can be configured using the membrane keypad on the front.
Inputs and outputs
The required analogue input can be selected when ordering:
- Resistance thermometer
- Thermocouple
- Current (4 to 20 mA)
- Voltage (0 to 10 V)
There is also a digital input for connecting a potential-free contact (not for resistance thermometers in three-wire circuit).
Depending on the device type, the following combinations are available as outputs: 2 relays (1 changeover contact, 1 NO contact), or 1 relay (NO contact) and 1 digital output DC 0/14 V, or 4 relays (NO contact).
USB device interface
The device has a Micro-B socket that is intended for connection to a PC for configuration with the setup programme. No separate power supply is required during configuration via the USB interface (USB-powered).
Electrical connection
The electrical connection is made using time-saving spring-loaded terminals (push-in technology)
Limit value monitoring
The device has three limit value monitors, each of which offers two configurable alarm functions. Any analogue signal is selected from a selector as the value to be monitored. The limit values can be defined either as an absolute value or as a different analogue signal. Additional functions:
- On/off delay
- Wiper function
- Alarm suppression during the switch-on phase or when parameters are changed
- Alarm latching
- Latching with acknowledgement
are available.
Comprehensive alarm and limit value functions can be realised with limit value monitoring.
Timer
After the timer is activated, a signal is output for the preset runtime, which can be inverted. The timer can also be started after a lead time has elapsed or a tolerance limit has been reached.
The service counter is used either to count the switching frequency of a binary signal or to determine its switch-on duration. As soon as the adjustable limit value is reached, a binary signal is activated and must be acknowledged. An operating hours counter is also available, which records the operating time of the device.
Setup programme
The optional setup programme enables the user to configure the device easily and conveniently via a PC. With this programme, data can be created, edited, transferred to the device and read out from there. It also offers a recording function for commissioning (start-up).
Customer-specific linearisation
Individual linearisation according to customer requirements makes it possible to use sensor signals with special characteristics. Programming is carried out in the setup programme either using your value table with up to 40 value pairs or using a formula (4th order polynomial)
Dimensions
Height | 11,4 cm |
---|---|
Length | 16,5 cm |
Width | 10,6 cm |
Weight
Weight | 200 g |
---|
Other attributes
Ausgang | 1 Relais (Wechsler AC 250 V, 10A) und 1 Relais (Schließer AC 250 V, 5A), ohmsche Last |
---|---|
Customs tariff number | 90303370 |
Eingang | 1 Widerstandsthermometer Pt100, Pt1000 in Zweileiterschaltung, 1 Digitaleingang |
Spannungsversorgung | AC 230 V, +10/-15 %, 48 bis 63 Hz |
Downloads:
Analog Input
0.4% from -80 °C
Designation |
Typ |
Norm |
Designation |
Type |
Standard |
ITS |
Measuring range |
Accuracy |
Fe-CuNi |
"L" |
DIN 43710 (1985-12) |
IPTS-68 |
-200 to +900 C |
0.4% IEC 60584-1:2013 |
Fe-CuNi |
"J" |
DIN EN 60584-1:2013 |
ITS-90 |
-210 to +1200 °C |
0.4% from -100 °C IEC 60584-1:2013 |
NiCr-Ni |
"K" |
DIN EN 60584-1:2013 |
2nd order digital filter; Filter constant adjustable from 0 to 100.0 sAccuracy refers to the measuring range.
ITS-90 |
-270 to +1300 °C |
0.4% from -80 °C |
intern or extern (konstant) |
Comparison point temperature |
Ambient temperature influence |
300 ppm/K |
Comparison agency |
500 A
internal or external (constant) |
Comparison point temperature |
0 °C (fixed) |
Speeds |
2nd order digital filter; Filter constant adjustable from 0 to 100.0 s |
Accuracya |
Measuring current |
Pt100 |
Designation IEC 60751:2008 |
Standard |
ITS |
Connection type |
Measuring range |
Accuracy |
Measuring current |
Pt100 IEC 60751:2008 |
DIN EN 60751:2008 |
ITS-90 |
2-/3-wire |
-200 to +600 °C |
0.25% |
500 A |
|
|
|
2-/3-wire |
-200 to +600 °C |
0.25% |
2nd order digital filter; Filter constant adjustable from 0 to 100.0 sAccuracy refers to the measuring range.
100 A |
Custom |
Sensor Line Resistance |
max. 30 per line |
Speeds |
150 to 3000 |
2.5 V
0.25% |
500 A |
Accuracya |
Input resistance or. Load tension |
Ambient temperature influence |
300 ppm/K |
Sensor Line Resistance |
> max. 30 per line |
Speeds |
2nd order digital filter; Filter constant adjustable from 0 to 100.0 s |
0,125 % |
2,5 V |
Designation |
Measuring range |
Accuracy |
2nd order digital filter; Filter constant adjustable from 0 to 100.0 sAccuracy refers to the maximum measurement range. At small measuring spans, the linearization accuracy is reduced.
Input resistance or load voltage |
Voltage |
0 to 10 V |
0.15% |
100 k |
Current |
Measuring Circuit Monitoring
++ = is recognized
4 to 20 mA |
0.125 % |
2.5 V |
Short circuit (sensor/line)) |
0 to 20 mA |
0.125 % |
2.5 V |
++ |
++ |
Ambient temperature influence |
100 ppm/K |
Measuring range under/exceeding |
according to NAMUR recommendation NE 43 (only current input 4 to 20 mA) |
Speeds |
2nd order digital filter; Filter constant adjustable from 0 to 100.0 s |
--- |
++ |
(+)a |
Strom 0 bis 20 mA |
--- |
Transmitter |
Measuring range below |
Exceeding the measuring range |
Short circuit (sensor/line) |
Fracture (sensor/conduction) |
Reverse polarity |
Resistance thermometer |
++ |
++ |
++ |
++ |
--- |
Thermocouple |
++ |
++ |
--- |
++ --- = is not recognized (+) = is conditionally recognized |
a depending on the set characteristic curve
Contact closed: Input is active (R
(+) |
Current 0 to 20 mAON< 1 kΩ) Contact open: Input is inactive (ROFF > 100 kΩ) |
DC 0/14 V 15 %
--- Switching capacity contact life |
++ 100,000 circuits at rated load |
--- |
--- Switching capacity contact life |
--- 100.000 Circuits at Rated Load |
|
++ Switching capacity contact life |
++ 100.000 Circuits at Rated Load |
++ |
++ Output signal current |
++ max. 20 mA (at nominal voltage 14 V) |
5 m
--- |
|
--- |
--- |
++ |
++ = is recognized |
Max. Length |
5 m |
0, 1 or automatic (configurable)
18-Segment-LCD-Anzeigen |
||
Digit height Color |
Input for potential-free contact function white |
Contact closed: Input is active (R ON |
Digits incl. decimal places |
4 |
1 relay (changeover) |
max. 10 A at DC 30 V or AC 250 V, resistive load |
Order Code 23 |
min. 1.5 mm2
1 relay (NO contact) |
max. 5 A at DC 30 V or AC 250 V, resistive load |
AC 230 V +10/-15 %, 48 bis 63 Hz |
||
max. 10 A at DC 30 V or AC 250 V, resistive load |
Order code 26 |
|||
DC 0/14 V 15 % |
DC 12 bis 24 V, ±15 % SELV |
|||
Electrical safety |
after DIN EN 61010, Teil 1 Overvoltage category II up to 300 V mains voltage, Degree 2 |
|||
USB device Typ 701580 |
Typ AC 230 V: max. 3,3 W |
Plug Type max. 3,6 W |
Micro-B (Socket) max. 1,7 W |
|
Standard |
Low-Speed, Full-Speed |
|||
Max. cable length |
5 m |
|||
Electrical connection |
on the back via spring-loaded clamps (Push-In-Technologie) |
|||
18-segment LCD displays |
|
|||
top display: 13 mm |
Bottom display: 4 mm |
|||
Digits incl. decimal places |
|
|||
7 |
Decimal places2, max. 1,5 mm2 |
|||
|
with plastic collar: min. 0,2 mm2, max. 0,75 mm2 |
|||
Stripping length |
8 mm |
|||
Power supply according to the ordered design |
|
|||
AC 230 V +10/-15%, 48 to 63 Hz |
min. 0,75 mm2 |
|||
05 |
AC 115 V +10/-15%, 48 to 63 Hz |
|||
16 A Load current |
30 |
Product Families Standard DIN EN 61326-1 Class B
DC 12 to 24 V, ±15% SELV Operation |
Electrical safety -10 bis +55 °C |
according to DIN EN 61010, Part 1 |
Power consumption |
Type AC 230 V: max. 3.3 W Operation |
Type AC 115 V: max. 3.6 W by class 3K3 |
Type DC 12 to 24 V: max. 1.7 W Operation |
Accuracy Timer by class 1M2 by class 2M2 by class 3M3 |
1 % Stability |
Sampling cyclea Industry Requirement |
a The product is suitable for industrial use as well as for household and small businesses
max. 154 g
250 ms |
Electrical connection |
on the back via spring-loaded clamps (push-in technology) |
Conductor cross-section, mechanical upper slant cobalt blue RAL 5013, lower slope silver-grey RAL 7001 |
Panel thickness |
Wire or stranded wire |
min. 0.2 mm2, max. 1.5 mm2 |
(without ferrule) |
Usage position |
Stranded wire with ferrule |
without plastic collar: min. 0.2 mm |
according to DIN EN 60529, front IP65, rear IP20 |
with plastic collar: min. 0.2 mm 2 |
Stripping length |
a The maximum permissible ambient temperature only applies to installation with vertical orientation of the display.
all versions
8 mm |
Conductor cross-section, electrical |
Certificates/Test Numbers |
5 A load current |
min. 0.75 mm2 |
10 A load current |
min. 1.0 mm2 |
16 A load current |
min. 1.5 mm2 CAN/CSA-22.2 No. 61010-1 (3. Ed.) |
all versions |
The device has approval if the relevant test mark is shown on the device.