Skip to main content

Testomat® LAB CL-R

Product number: 116116

Product information "Testomat® LAB CL-R"

The Testomat® LAB CL and the Testomat® LAB CL-R are robust, wet chemical online measuring converter to measure the concentration of total chlorine or free chlorine in the measuring range 0 - 5 mg/l. The instrument is suitable for controlling the water quality of water treatment plants, drinking water plants, process water monitoring and for monitoring the chlorine concentration in the cooling tower process.
Instrument operation is based on the DPD method according to EN ISO 7393-2. The analysis is carried out through the addition of two reagents and the measurement result is obtained after a reaction time of approx. 60 seconds (pure measurement time without flush time).
Please note that Testomat® LAB CL and Testomat® LAB CL-R are developed for use in multi-parameter concepts or for integration into an existing higher-level controlconcept.
In addition to the 4-20 mA output for the transmission of the measured values, this series has an RS232 interface for the transmission of the measured values and error & status messages. Furthermore, all data are continuously recorded on the integrated SD card or optionally available SDHC card (2Gbyte) as a file in CSV format in a structured way and can be used for detailed observations at any time.

The Testomat® LAB CL and CL-R convinces with new functionalities:
  • Execution of parameterization by SD card or the "Service Monitor" software via mini-USB (on the device side) to USB 2.0 (for example PC/notebook)
  • Multilingual menu navigation software in German, English, French, Dutch, Portuguese
  • Firmware update via SD card
  • compact design
  • optimized water detection based on an optical measuring method
  • optimized reagent set for total chlorine measurement (reduction from three to tow reagents for total chlorine)
  • Integrated self-test with continuous monitoring
  • Automatic venting of the indicator line 

Tried and tested performance profile: 
  • High-precision peristaltic pumps
  • Reliable and low-maintenance operation
  • Minimal reagent and water consumption
  • Analog output 4 - 20 mA for transmission of measured values
  • RS232 interface for transmission of measured values & fault messages
  • Common alarm output
  • Optimised reagents: Only 2 reagents for the determination of total chlorine
  • Optimised reagent bottles: Filling quantities adjusted so that both bottles are used up at the same time

Additional functions of the CL-R version: 
  • Parameterisation and readout of the unit parameters via the RS232 interface

Analysis triggering:

  • Automatic interval operation (interval pause adjustable from 10-60 minutes)
  • Measuring phase mode (start impulse triggers a sequence of analyses for a period of 10 minutes to 12 hours)
  • External analysis input (start/stop)
  • Hand start

Dimensions

Height 21 cm
Length 43 cm
Width 35 cm

Weight

Weight 4,55 kg

Other attributes

Country of origin EU
Customs tariff number 90278990
Technical data
Operating voltage: 24 VDC
Power consumption: Max. 1 A, without external load
Protection class: I
Protection: IP 40 (when using the optionally available device cover, IP43)
Ambient temperature: 10–40 °C
Water temperature: 10–40 °C
Dimensions (W x H x D):     270 x 350 x 147 mm
Operating pressure: 1 to 8 bar / 1x105 to 8x105 Pa or 0.3* to 1 bar / 1x105 to 1x105 Pa (*after removing the regulator core)
Weight: approx. 4.35 kg
Menu Language: (Servicemonitor) German, English, French, Dutch
Measuring range:0-5 mg/l (ppm) free chlorine | 0-5 mg/l (ppm) total chlorine 

We recommend the following accessories

Testomat® LAB OLED display module for measured value visualization
Product number: 37764
256x64 2,8", yellowFeatures: When the device is switched on with the display plugged in, the installed software version is displayed during the boot process. This  allows you to visually check the current software version after a software update. After a measurement has been completed, the measurement result is  shown in the selected display unit. The display value is retained until the end of the next measurement and is then updated to the new measured value. If a fault occurs during the last measurement, the display shows “xx x x x selected display unit”. If it is a temporary fault, the Alarm function key flashes at the same time (see Temporary faults in the manual). In this case, the device will start a new measurement once the programmed analysis interval has expired. If the error is still present, the indication on the display remains and  the Alarm function key remains illuminated. In this case, no further measurements are made during programmed analysis interval and the device switches to standby mode. If the fault is no longer present, the measurement result is shown on the display once the measurement has been completed and the device switches back to normal operating mode. 

€560.10*
Connection Set for Testomat 2000® / ECO / EVO / LAB
Product number: 40187
In diesem Anschluss-Set ist alles enthalten, was Sie für den schnellen Anschluss des Testomat 2000®- oder Titromat®-Gerätes benötigen.   Inhalt: 5 m Kunststoffrohr PE 6/4x1,blau 2 m Ablaufschlauch di = 12 mm 1 Kugelhahn, PPSV 011223W 1 Reduzier-Verbinder 10 auf 6 mm 1 Reduziernippel 3/8"-1/2"

€134.60*
Instrument cover for Testomat® LAB instruments
Product number: 37798
Recommended for Testomat® LAB instruments which are exposed to sunlight.

€536.10*
Testomat® LAB CL chlorine reagent set F (free chlorine) 2x 500 ml AF & 1 x 400 ml B
Product number: 158234
The bottles of original Testomat® LAB CL chlorine reagent Set F can be used immediately in the Testomat 2000® LAB CL without cumbersome filling and refilling.Contents:2 x 500 ml bottle AF reagent 1 x 400 ml bottle B reagent

€339.60*
Testomat® LAB CL Chlorine reagent set T (total chlorine) 2 x 500 ml AT, 1 x 400 ml B
Product number: 158239
The bottles of original Testomat® LAB CL chlorine reagent Set T can be used immediately in the Testomat 2000® LAB CL without cumbersome filling and refilling.Contents:2 x 500 ml bottle AT reagent1 x 400 ml bottle B reagent

€345.20*
Service set Testomat® LAB CL and Monochloramine
Product number: 270356
A special service set is available for Testomat® LAB CL and Monochloramine, which contains important spare parts, among other things.Contents:1 x gasket set T20002 x sight glasses 30x31 x flow controller core3 x plugs for measuring chamber2 x screw cap with insert T20001 x filter screen for inlet 19,5dx255 x different tubes1 x set of cleaning brushes1 x pump head2 x hose connectors2 x gasket hose adapter

€425.70*