Skip to main content Skip to search Skip to main navigation

Testomat® LAB CL and LAB TH instrument combination

Product number: 900520

Product information "Testomat® LAB CL and LAB TH instrument combination "

The Testomat® EVO TH automatically determines the water hardness by means of titration. The device is suitable for controlling the water quality of water treatment plants, drinking water systems, industrial boilers and for monitoring process water. 

Approved for boiler houses | component identification no.: TÜV. WÜH. 21-025 | VdTÜV bulletin water monitoring device 100 and UL-TÜV certified.

The Testomat® EVO TH convinces with new functionalities:
  • Optical water detection when filling the measuring chamber
  • Import and export of settings (basic programming) with selectable file name
  • Logging of measurement data and messages / alarms using an integrated SD or optional SDHC card (2GByte)
  • Firmware update via SD card
  • LCD graphic display
  • Multilingual menu with easy switching (internal programming is retained)
  • Integrated self-test with continuous monitoring
  • External clear / acknowledge input
  • Free programmable password
  • Automatic bleeding of the indicator line
  • Doors can be changed individually
  • Range monitoring (fall below limit value1 / exceed limit value 2)
  • Permitted number of lack of water, freely programmable (for systems with temporarily low water pressure)
Performance profile:
  • High-precision titration using a piston dosing pump
  • Analogue output 0/4 - 20 mA
  • Programmable hardness unit in ° dH, ° f, ppm CaCO3, mmol / l
  • 2 independent limits with adjustable switching functions as well as switching option in accordance with an adjustable number of negative
  • analyzes
  • Analysis initiation:
    • automatic interval operation (0-99 minutes)
    • depending on quantity via contact water meter
  • Indicator quantities: 100 und 500 ml bottles 
The Testomat® EVO TH is supplied without a power switch. This is done to comply with the DIN EN 61010-1 safety standard for measuring, control and laboratory equipment. Of course, an external mains switch will be made available to you as a customer for purchase. You can order this from us as a disconnector under article no. 850925, "external cam switch with protection class IP65".
The Testomat® LAB TH and Testomat® LAB TH-R (Remote)determine the water hardness (residual total hardness) fully automatically by titration. The instrument is suitable for controlling the water quality of water treatment plants, drinking water plants, industrial boilers and for monitoring process water.
Please note that Testomat® LAB - TH and Testomat® LAB TH-R was developed for use in multi-parameter systems or for connection to a higher-level control system.
In addition to the 4-20 mA output for transmitting the measured values, this series has an RS232 interface for transmitting the measured values and error & status messages. Furthermore, all data are continuously recorded on the integrated SD card or optionally available SDHC card (2Gbyte) as a file in CSV format structured and can be used at any time for detailed observations.

The Testomat® LAB TH and TH-R convinces with new functionalities:
  • Execution of parameterization by SD card or the "Service Monitor" software via mini-USB (on the device side) to USB 2.0 (for example PC/notebook)
  • Multilingual menu navigation software in German, English, French, Dutch, Portuguese
  • Firmware update via SD card
  • compact design
  • optimized water detection based on an optical measuring method
  • Integrated self-test with continuous monitoring
  • Automatic venting of the indicator line
Tried and tested performance profile:
  • High-precision titration using a piston dosing pump
  • Reliable and low-maintenance operation
  • Minimal indicator and water consumption
  • Analog output 4 - 20 mA for transmission of measured values
  • Programmable hardness unit in °dH, °f, ppm CaCO3, mmol/l
  • Common alarm output
  • Indicator quantities: 500 ml bottles
Analysis triggering:
  • Automatic interval operation (interval pause adjustable from 0-255 minutes)
  • External analysis input (start/stop)
  • Hand launch
Both analysers are available in the "R" version, which includes the following additional function:
  • Parameterisation and readout of the unit parameters via the RS232 interface
Optional accessories for both devices:
  • OLED display
  • Protecting cover to increase the IP protection class

The Testomat® EVO TH automatically determines the water hardness by means of titration. The device is suitable for controlling the water quality of water treatment plants, drinking water systems, industrial boilers and for monitoring process water. 

Approved for boiler houses | component identification no.: TÜV. WÜH. 21-025 | VdTÜV bulletin water monitoring device 100 and UL-TÜV certified.

The Testomat® EVO TH convinces with new functionalities:
  • Optical water detection when filling the measuring chamber
  • Import and export of settings (basic programming) with selectable file name
  • Logging of measurement data and messages / alarms using an integrated SD or optional SDHC card (2GByte)
  • Firmware update via SD card
  • LCD graphic display
  • Multilingual menu with easy switching (internal programming is retained)
  • Integrated self-test with continuous monitoring
  • External clear / acknowledge input
  • Free programmable password
  • Automatic bleeding of the indicator line
  • Doors can be changed individually
  • Range monitoring (fall below limit value1 / exceed limit value 2)
  • Permitted number of lack of water, freely programmable (for systems with temporarily low water pressure)
Performance profile:
  • High-precision titration using a piston dosing pump
  • Analogue output 0/4 - 20 mA
  • Programmable hardness unit in ° dH, ° f, ppm CaCO3, mmol / l
  • 2 independent limits with adjustable switching functions as well as switching option in accordance with an adjustable number of negative
  • analyzes
  • Analysis initiation:
    • automatic interval operation (0-99 minutes)
    • depending on quantity via contact water meter
  • Indicator quantities: 100 und 500 ml bottles 
The Testomat® EVO TH is supplied without a power switch. This is done to comply with the DIN EN 61010-1 safety standard for measuring, control and laboratory equipment. Of course, an external mains switch will be made available to you as a customer for purchase. You can order this from us as a disconnector under article no. 850925, "external cam switch with protection class IP65".
Technical data:

Testomat EVO TH

Supply voltage: switching power supply 100-240 VAC, 100-353 VDC
Power consumption: max. 30 VA
Protection class: I
Protection: IP 65
Ambient temperature: 10–40 °C
Water temperature: 10–40 °C
Dimensions (W x H x D): 380 x 480 x 280 mm
Operating pressure: 1 bis 8 bar / 1x105 bis 8x105 Pa Oder 0,3* bis 1 bar / 0,3x105 bis 1x105 Pa (after removal of the valve body)
Weight: approx. 9,0 kg
Menu Language: German, English, French, Dutch, Spanish, Turkish, Chinese, Czech, Russian (others on request)
Measuring range: Water hardness: 0.89 - 448 ppm
Testomat LAB TH
Operating voltage: 24 VDC
Power consumption: Max. 1 A, without external load
Protection class: I
Protection: IP 40 (when using the optionally available device cover, IP43)
Ambient temperature: 10–40 °C
Water temperature: 10–40 °C
Dimensions (W x H x D): 270 x 350 x 147 mm
Operating pressure: 1 to 8 bar / 1x105 to 8x105 Pa or 0.3* to 1 bar / 1x105 to 1x105 Pa (*after removing the regulator core)
Weight: approx. 4.35 kg
Menu Language: (Servicemonitor) German, English, French, Dutch
Measuring range: 0.89 - 448 ppm