Contains:
2 x Sight glass windows 30x33 x Flat gasket 24x2 EPDM 601 x Bottle insert for screw cap and push-fit suction tube, 100 ml bottle1 x Bottle insert for screw cap and push-fit suction tube, 500 ml bottle1 x brushes set
Contains:
2 x Sight glass windows 30x33 x Flat gasket 24x2 EPDM 601 x Bottle insert for screw cap and push-fit suction tube, 500 ml bottle1 x brushes set
The cleaning brush sets are equipped with a sun head so that you can clean the measuring chamber faster and more thoroughly. In addition, the brushes absorb the dirt better thanks to their dense bristles.[#dspacer#][#dspacer#]Consist:1x #895218 cleaning brush Ø 6mm1x #895219 cleaning brush Ø 16mm
1x #895220 cleaning brush Ø 20mm
Repair and maintenance case T2000/EVO TH/ECO for professionals Content: 15 x plugs for measuring chamber5 x filter screens for feed 19.5dx252 x springs for feed5 x flow regulator cores, complete10 x O-rings 10.82x1.7810 x O-rings 20x25 x O-rings 4.47x1.785 x O-rings 18x2 EPDM20 x flat gaskets 24x2 EPDM 606 x fuses, G-, 5x20 mm, M4A6 x (solderable) fuses TR5, T 0.2A6 x (solderable) fuses TR5, T 0.315A6 x (solderable) fuses TR5, T 1.0A6 x (solderable) fuses TR5, T 0.1A6 x (solderable) fuses TR5, T 0.08A6 x (solderable) fuses TR5, T0.16 A1 x set of brushes15 x cylindrical protection plugs with shoulders 5.3dx5 natural PE5 x O-rings 4,47x1,785 x O-rings 18x2 EPDM20 x flat seals 24 x 21 x Assortment box Testomat® />10 x inspection glasses, 30x31 x suction hose complete1x pressure hose, complete2 x magnetic stirring cores3 x screw caps with insert1 x table of contents2 x PE D=6, d=4x105 pipes2 x PE D=6, d=4x115 pipes2 x PE D=10, d=8x98 pipes2 x p
Repair and Service Case Testomat® 808Case for regular maintenance of a Testomat® 808 and on-site service with lots of content. Content: 8 3.68x1.78 O-rings8 1.78x1.78 O-rings8 4.5x1.5 O-rings8 24x2 flat gaskets1 pump head4 500ml inserts with screw cap1 100ml insert with screw cap1 cleaning brush set4 angle screw connectors6 fuses, T 0.1 A6 fuses, T 0.2 A6 fuses, T 1.0 A6 fuses, T4A6 30x3 sight glasses2 pipes, l = 53 mm2 pipes, l = 140 mm1 optical board1 SUB-D null modem cable1 USB serial adapter2 dosing needles4 hose adapters2 magnetic stirring bars8 M3x12 screws4 M3x40 screws1 LED socket1 magnetic valveDocumentation/software (1)
Contents: 1 x 37570 Solenoid valve complete Testomat® 808 2 x 37580 Insert with screw cap and suction tube 100ml bottle 1 x 37859 double pump head Testomat® 808 1 x 31972 SUB-D null modem cable, 9-pin, 2 x socket, 3m 4 x 37579 Insert with screw cap and suction tube 500ml bottle 2 x 40050 Magnetic stirring core 4 x 37538 Tube adapter Testomat® 808 4 x 40157 Angle screw-in connector, G1/8"-6 2 x 37543 Pipe, PE, D=6 d=4 L=53mm 2 x 37544 Pipe, PE, D=6 d=4 L=140mm 6 x 40170 Viewing window 30x3 6 x 31595 Fuse solder-in, TR5, T0,1A 6 x 31592 Fuse solder-in, TR5, T1,0A 6 x 31584 Fuse, solder-in, TR5, T0.2A 6 x 31585 fuse, T0,315A 8 x 33797 O-ring 3,68 x 1,78 8 x 31666 Fuse G-, 5x20mm, T4A 8 x 33777 Flat gasket 24x2 EPDM 70 4 x 33253 Screw M3x40, A2, DIN 965 8 x 33246 pan-head screw M3x12 DIN 7985H A2 8 x 11264 O-ring 4.5 x 1.5 8 x 11245 O-ring 1,78x1,78 1 x 32286 Adapter USB > Serial -length 1.1 meter 1 x 32287 Cleaning brush set 1 x 37498 USB stick with software tool for T808 and maintenance manual 2 x 37621 Dosing needle Testomat® 808 completeTranslated with www.DeepL.com/Translator (free version)
Content: 2 x 40170 sight glass 30x33 x 33777 flat gasket 24x2 EPDM 602 x 33776 O-Ring 18x2 EPDM3 x 11210 Protection plug to measuring chamber T2000 / ECO / EVO TH / EVO TH CAL1 x 40050 Magnetic stirring core
Contains:
2 x Sight glass windows 30x33 x Flat gasket 24x2 EPDM 601 x Bottle insert for screw cap and push-fit suction tube, 500 ml bottle1 x Pump head, complete2 x Hose adapter 1 x brushes set
Service set contains:2 x sight glasses 30 x 33 x flat gasket 24 x 21 x insert for screw cap & suction tube 100 ml bottle1 x insert for screw cap & suction tube 500 ml bottle1 x double pump head conversion kit1 x gear motor2 x Hose connector1 x Cleaning brush set
Important: After replacement, the pump must be recalibrated in Testomat® 808 SiO2.The adjustment is available from firmware version T808_83-003. Carry out a firmware update for older versions before performing the adjustment! (Serial number less than 253.061)For this calibration, it is important that you use water with a silicate content of 0 ppm, otherwise the zero point calibration will be incorrect and lead to false measurement results.To ensure this, please use the silicate filter cartridge specially developed for this process for the T808 SiO2, article 270344.(For additional information and instructions on the equipment you need for the software update, please refer to the operating instructions. The instructions "Replacing the pump head on Testomat® 808 SiO2" are also available)
This special service set is designed for the Testomat 2000® PO4. Included are the standard spare parts for the Testomat 2000® together with spare parts for the PeriClip® pump, i.e. the pump head.
The service set includes the following spare parts:
1 T2000 gasket kit
2 30x3 sight glass
1 flow regulator cores
3 stoppers for m. chamber
2 x pump head
1 filter screen for intake
3 different pipes
1 cleaning brush set
2 x tube connection
2 x seal for tube connection
1 x screw cap with insert for 500 ml bottle
1 x screw cap with insert for 100 ml bottle
This special service set is designed for the Testomat 2000® Polymer. Included are the standard spare parts for the Testomat 2000® together with spare parts for the PeriClip® pump, i.e. the pump head.
The service set includes the following spare parts:
1 T2000 gasket kit
2 30x3 sight glass
1 flow regulator cores
3 stoppers for m. chamber
2 x pump head
1 filter screen for intake
3 different pipes
1 cleaning brush set
2 x tube connection
2 x seal for tube connection
2 x screw cap with insert
This service kit contains all the spare parts for the regular maintenance of Testomat 2000®, Testomat ECO®, Titromat® or Testomat® EVO TH instruments.
Content:
1 T2000 gasket kit
2 30x3 sight glass
1 flow regulator cores
3 stoppers for measuring chamber
1 valve kit for injection pump
1 filter screen for intake 19.5 d x 25
3 different pipes
1 cleaning brush set
Service Set Testomat® Testomat® EVO TH / Testomat ECO®/Titromat®
Content:
1 x gasket kit T2000
2 x sight glass windows 30x3
1 x flow regulator core, complete
3 x cylindrical protection plug with shoulder 5.3dx5 PE
1 x set of valves for the injection pump
1 x filter screen for feed 19.5dx25
3 x different pipes
3 x cleaning brush
Set with all the parts, you need for the maintenance of Testomat® 808 and Testomat® 808 SIOConnection set consists of: 15 Flat seal 24 x 2 6 Sight-glass window 30 x 3 6 O-ring 3,68 x 1,78 6 O-ring 4,5 x 1,5 6 O-ring 1,78 x 1,78 1 Pipe, PE, D=6 d=4 L=53mm
A special service set is available for Testomat® LAB CL and Monochloramine, which contains important spare parts, among other things.Contents:1 x gasket set T20002 x sight glasses 30x31 x flow controller core3 x plugs for measuring chamber2 x screw cap with insert T20001 x filter screen for inlet 19,5dx255 x different tubes1 x set of cleaning brushes1 x pump head2 x hose connectors2 x gasket hose adapter
There is a separate service set especially for Testomat® LAB TH, which contains important spare parts.
The service set includes the following spare parts:
1 T2000 gasket kit
2 sight glasses 30x3
1 flow regulator core
3 measuring chamber plugs
1 filter screen for intake
5 different pipes
1 cleaning brush set
2 x screw cap with insert for 500 ml bottle
Dear customers, please note that the calibration of the Testomat® 808 SiO2 can only be carried out with silicate-free water. Therefore, please use the silicate filter cartridge specially developed for this purpose when replacing the double pump head (art. no. 40395) and the associated pump adjustment.The cartridge filled with the special resin is inserted into the sampling line of the unit before the inlet and removed again after the adjustment. The pump replacement instructions describe the use of the silicate filter, storage conditions and shelf life. After the first use, the filter can be used up to 10 times within one year for balancing. After one year, the filter must be disposed of.