Data logger, developed for Testomat 2000® and ®Titromat with network connection for remote enquiry and maintenance. Technical DataThe network logger plug-in card for Testomat 2000® is a miniature computer with network connection, webserver, FTP server and integrated flash memory8 MB flash memory for 400000 measured values and notifications (over a period of 5 years)? Generation of one measuring and onealarm file per monthFiles are stored in CSV format and can be edited with a spreadsheet softwareDisplay the current measured values and the last alarm on a web browserGraphic display of the monthly measuring values on a web browserNotification of new measured values, alarms/notifications and limit values being exceeded via emailFile download by browser or FTPForwarding of all notifications and measured values to any TCP/IP port for linking systems with SPS and other network-enabled devicesPassword protection for all settings, FTP and web accessAuto-MDI-X
Plug-in card for connecting Testomat 2000® to a protocol printer via the
serial interface RS232, suitable for Testomat 2000® and Titromat® instruments.
Technical Data
for connecting a log printer or protocol converter
(field bus, Ethernet, etc.)
The data logger, which is inserted into the Testomat 2000® or Titromat® instrument as a plug-in card, saves the measuring results and fault messages on an SD card.
Technical Data
The data is available in CSV format and can be further processed or analysed in a spreadsheet.
including standard SD Card up to 2 GB
It is necessary to make a software update for older devices, before the data logger can be used.
Plug-in card for a voltage interface, suitable for Testomat 2000® and Titromat® instruments.
Technical Data
output voltage: 0/2-10V
galvanic isolation:
256x64 2,8", yellowFeatures:
When the device is switched on with the display plugged in, the installed software version is displayed during the boot process. This
allows you to visually check the current software version after a software update. After a measurement has been completed, the measurement result is
shown in the selected display unit. The display value is retained until the end of the next measurement and is then updated to the new measured value. If a fault occurs during the last measurement, the display shows “xx
x x x selected display unit”. If it is a temporary fault, the Alarm function key flashes at the same time (see Temporary faults in the manual). In this case, the device will start a new measurement once the programmed analysis interval has expired.
If the error is still present, the indication on the display remains and
the Alarm function key remains illuminated. In this case, no further measurements are made during programmed analysis interval and the device switches to standby mode. If the fault is no longer present, the measurement result is shown on the display once the measurement has been completed and the device switches back to normal operating mode.
The data logger with USB connection can be used in Testomat® 808 devices.
It provides a protocol of the readings and notifications of the Testomat® 808 using the 20mA current loop. Data access is performed via the built-in USB port.
Technical Data
Monitors the Testomat® 808 continuously.
Storage capacity for 32000 samples. Assuming a typical interval pause time of 15 minutes, 10 months data can be captured.
Battery lifetime more than 1 year
Data access via USB port
Drivers and application usable with Windows XP, Windows Vista, Windows 7 and Windows 8 (32 und 64 bit) operating systems
Readings are shown in web browser in HTML format in table format with timestamp. Printable directly from browser.
In addition readings are stored in CSV format for convenient post processing with office software