Skip to main content Skip to search Skip to main navigation

JUMO contact resistance thermometer with connection cable and mounting hole, aluminium protective fitting

Product number: 802084

Product information "JUMO contact resistance thermometer with connection cable and mounting hole, aluminium protective fitting "

Contact resistance thermometer with mounting hole Protective fitting aluminium

Typ: 902550/10-386-1003-1-11-2500/000

  •  Temperature range from -50 to +260°C (PTFE)
  •  1× Pt100 in two-wire circuit
  •  Tolerance class according to DIN EN 60751: Class B (standard)
  •  Connection cable end: Wire end ferrules to DIN 46228 Part 4 (standard)
  •  Connection length in mm: 2500 mm
  •  Extra code: without
  •  Suitable for round and flat surfaces
  •  Quick and uncomplicated installation
  •  with protective fittings made of various materials
  •  Low thermal mass
  •  Optimum heat transfer from the measuring point to the sensor

Contact resistance thermometers are ideal for precise temperature measurements on closed pipe systems and other round or flat surfaces. The uncomplicated mounting with tensioning straps or hose clamps eliminates the need for mechanical processing of the measuring point.
Indirect temperature measurement guarantees interference-free temperature measurement, unaffected by flow, pressure or chemical influences. Due to the low thermal mass of the measurement object, the influence is kept to a minimum. Heat-conducting paste is available as an option to optimise heat transfer.
Large temperature differences between the measured medium and the environment are directly reflected in the measurement; additional insulation is recommended here.
A Pt100 temperature sensor in accordance with DIN EN 60751 Class B is installed as standard in a two-wire circuit, but variants with Pt500, Pt1000 are also possible. 

Dimensions

Height 1 cm
Length 25 cm
Width 20 cm

Weight

Weight 55 g

Other attributes

Anschlussleitung PTFE
Customs tariff number 90251900
Messeinsatz 1x Pt 100 Zweileiterschaltung
Temperaturbereich -50°C ... +260°C
Technical data

for basic type 902554/44 optional analog transmitter, 4 to 20 mA or 0 to 10 V

Cable ends tin-plated, available with ferrules, with receptacles or multi-pin connectors

Flex

Silicone, ambient temperature -50 to +180 °C

PTFE, ambient temperature -190 to +260 °C

Kapton, ambient temperature -50 to +260 °C

Connection Housing

Basic type 902554/41 and 902554/42 Plastic housing PC, colour silver-grey/blue Basic type 902554/44 Plastic housing PC, colour white

Connection via screw terminals, basic type 902554/44 optionally

available with spring-loaded clamps if selected without transmitter

Protective Tube

Stainless steel 1.4571, aluminum, plastic

Measuring insert

Pt100 Temperature Sensor, DIN EN 60751, Class B, Two-Wire Circuit

Transmitter

for basic type 902554/44 optional analog transmitter, 4 to 20 mA or 0 to 10 V

 

EN 61326 Class B, Industrial Requirements

 

 

Exit 4 bis 20 mA

Exit 0 bis 10 V

Entrance

Input Sensor current

Sampling Rate

 

Output 4 to 20 mA

 0,5 mA

Continuous measurement, because analog signal

 

Output 0 to 10 V

 0,5 mA

Continuous measurement, as analogue Signal

Input Measurement Input Sensor Current

 

Measurement Rate

Sensor and cable rupture

 

Pt100 (DIN EN 60751)

 0.5 mA

continuous measurement, due to analogue signal path

 

Pt100 (DIN EN 60751)

 0.5 mA

continuous measurement, due to analogue signal path

 11 bis < 14 V (typisch 12 V)

Measuring Circuit Monitoring Measuring Range Below Measurement Range Exceeding Measuring Range Exceeding

 

 

Exit

imprinted direct current 4 bis 20 mA

DC voltage 0 bis 10 V

Output

Imprinted direct current 4 to 20 mA

DC voltage 0 to 10 V

Transmission behavior

Temperature linear

Temperature linear

Transmission accuracy

 ±0.1%

 ±0.2%

Damping of residual ripple

 

 

a 24 V power supply,

 

 

Amplitude 10 V/50 Hz, Load 470 /Load 10 M

Rb = (Ub - 7,5 V) ÷ 22 mA

-

Burden (Rb)

Rb = (Ub - 7.5 V) ÷ 22 mA

-

Burden influence

 ±0.02 %/100 a

-

Load/Load Influence

-

 10 k/ ±0.1 %

Setting time in case of temperature change

 10 ms

 10 ms

Matching conditions

DC 24 V/approx. 22 °Ca,b or  ± 0,2 K

DC 24 V/approx. 22 °Ca,b or  ±0,2 K

Matching accuracy

 ±0.2 %

 ±0.2 %

 

±0.4 K (typical) at 20 °C/24 V

±0.4 K (typical) at 20 °C/24 V

Power supply

Power supply (Ub) Reverse ol.protection

Power Supply Influence

 

Power supply

ja

 ±0,01 %/V Abweichung von 24 Va

 

Power supply

 ±0,01 %/V Abweichung von 24 Va

Power Supply Power Supply (Ub) Reverse Polarity Protection

 

 

Environmental impact

-40 bis + 85 °C

-40 bis + 85 °C

Temperature range

-40 to + 85 °C

-40 to + 85 °C

Storage temperature range

-40 to +100 °Ca

-40 to +100 °Ca

Temperature

similar DIN EN 60654 Klasse C1

 ±0.01 %/K deviation from 22 °C

 ±0.01 %/K deviation from 22 °C

Climatic resistance

relative humidity  95 % annual average without condensation

relative humidity  95 % annual average without condensation

a All figures refer to the full scale of 20 mA.

b The greater value is valid.

Type suffix 058

 

EMC Emission / Immunity

EN 61326 Class B, Industrial Requirements

EN 61326 Class B, Industrial Requirements

Test basis

gilt für

SIL QUALIFIED PL QUALIFIED

-

Mark

Checkpoint

Certificate/Test Number

in conjunction with the manufacturer's declaration