Skip to main content Skip to search Skip to main navigation

JUMO data logger with 1 Ethernet port, 2 USB ports (1 host, 1 device), and 1 RS232/485 port, as well as a relay (changeover contact)

Article number: 802139
Our service hotline – We are here for you 📞 +49 (0) 5121 7609 99

Product information "JUMO data logger with 1 Ethernet port, 2 USB ports (1 host, 1 device), and 1 RS232/485 port, as well as a relay (changeover contact) "

JUMO LOGOSCREEN 601 – Screen recorder with touchscreen (Type: 706521/08-000-23/000)

The JUMO screen recorder enables continuous recording and visualization of process states. At the same time, secure data storage ensures that measured values can be reliably documented and protected against manipulation.

The JUMO LOGOSCREEN 601 is a powerful screen recorder for the graphical display, monitoring, and secure recording of process data. Thanks to its intuitive touch operation and versatile connection options, the device is suitable for demanding industrial applications.

Equipment of this device variant

  • Power supply: AC 110–240 V (+10 / -15 %), 48–63 Hz
  • 1 Ethernet interface
  • 2 USB interfaces (1 × Host, 1 × Device)
  • 1 RS232/RS485 interface (switchable)
  • 1 relay output (changeover contact)
  • intuitive operation via touchscreen
  • integrated web server for online visualization
  • recording of process and batch data

Functions and features

The LOGOSCREEN 601 offers extensive functions for process monitoring and data analysis:

  • graphical display of process data in real time
  • recording and archiving of measured values
  • batch logging for processes requiring documentation
  • limit value monitoring with up to 24 channels
  • timer and event functions for controlling processes
  • optional flow measurement as well as counting and integration functions

In addition, custom applications can be implemented using Structured Text (ST code) (type addition).

Operation & configuration – intuitive concept of the JUMO LOGOSCREEN 601 screen recorder

Operation is performed via an intuitive touchscreen menu with symbol-based navigation. An integrated user management system protects the device against unauthorized access.

In the standard version, multiple users with individual rights can be created.

Using the setup program of the JUMO LOGOSCREEN 601

Configuration can be conveniently carried out via a PC program. Among other things, the following options are available:

  • creation and customization of process screens
  • definition of user rights
  • management of batch texts and logs
  • backup and transfer of configuration data

Versatile visualization & display options

The device offers different display types for process data:

  • curve displays for analog values
  • display of digital states
  • individually designable process screens

Custom visualizations can be created using the integrated process screen editor. Up to 100 objects can be integrated per screen.

Interfaces & communication of the JUMO screen recorder

The LOGOSCREEN 601 offers extensive communication options:

Ethernet

  • data transfer and archiving
  • web server function
  • communication with PC systems
  • time synchronization

USB

  • data export via USB flash drive
  • connection to the setup program

RS232 / RS485

  • communication with Modbus systems
  • connection of external devices (e.g. barcode scanners)

The device can optionally be integrated into PROFINET networks.

Inputs, outputs & expandability

The screen recorder can be expanded flexibly and supports various signal types:

  • analog inputs for temperature, current, voltage, and resistance signals
  • digital inputs and outputs for process control
  • configurable analog outputs (optional)

A relay output is included as standard and can be used for alarm or switching functions.

Data storage & security

Measured data is continuously recorded and stored in an internal memory.

  • internal memory up to 1 GB
  • ring memory principle (older data is overwritten)
  • automatic monitoring of storage capacity
  • encrypted data storage

Various options are available for securing the data:

  • export via USB
  • transfer via Ethernet
  • automatic data readout via PC software

An integrated battery ensures that data remains protected in the event of a power failure.

Evaluation & software

Suitable PC programs are available for further data processing:

  • PCC – automatic data readout
  • PCA3000 – archiving, visualization, and analysis
  • optional: user management and audit trail (e.g. for FDA requirements)

Detailed explanation of the functionalities of the JUMO LOGOSCREEN 601

Operating language

The device offers a selection of different operating languages. These languages can be edited and exchanged using the setup program. The following languages are currently available:

  • German
  • English
  • French
  • Spanish
  • Czech
  • Chinese
  • Russian
  • Italian

It is also possible to create custom language versions that support Unicode.

Process screen editor

The setup program allows the user to create 6 customized process screens and transfer them to the screen recorder. These screens are used for displaying process data as well as entering texts and process values. Each process screen can consist of up to 100 objects (images, analog channels, digital channels, texts, …).

Interfaces

USB

The screen recorder is equipped as standard with two USB interfaces. A USB storage stick can be connected via the host interface on the front. The device interface on the back (Micro-B type) is used to connect to a PC (for the setup program or PCC/PCA3000). To ensure IP66 protection at the front, the USB host interface is fitted with a cover.

Ethernet

As standard, the screen recorder is equipped with an Ethernet interface that supports various functions:

  • email dispatch via SMTP server
  • time synchronization via SNTP server
  • communication with a PC (setup program, web server, data archiving with PCC/PCA3000)
  • communication with Modbus master/slave

The IP address can be configured manually or assigned automatically by a DHCP server. DNS use is also supported. In addition, RS232/RS485 interfaces are available.

RS232/RS485

This standard interface can be switched between RS232 and RS485 by configuration. It is used for communication with a Modbus master or Modbus slave. It is also intended for the connection of a barcode scanner.

PROFINET IO Device

Optionally, the screen recorder can be equipped with a PROFINET interface in order to integrate it as an IO device into a PROFINET network. This interface also allows simultaneous use of Ethernet standard services, making the standard Ethernet interface unnecessary. A GSD file (GSDML) describing the properties of the screen recorder is available for the IO controller programming system.

External inputs via interface

The interfaces (Ethernet, RS232/RS485) allow the screen recorder to access 24 external analog inputs and 24 external digital inputs. In addition, up to 10 texts for batch logs and 4 event texts with a length of up to 160 characters can be transmitted.

In addition, up to 10 texts for batch logs and 4 event texts with a length of up to 160 characters can be transmitted; Modbus TCP and Modbus RTU are used for this purpose.

Inputs and outputs

The screen recorder is available in different device variants with analog and digital inputs and outputs (options). The analog inputs (maximum 6) are versatile measuring inputs for:

  • resistance thermometers
  • thermocouples
  • resistance potentiometers/WFG
  • resistance/potentiometer
  • standard signals (current, voltage)

Each of the up to 2 analog outputs can be used flexibly either as a voltage output in the range from 0 to 10 V or as a current output with 0/4 to 20 mA.

The digital inputs (maximum 12) and the individually switchable digital inputs/outputs (12) are operated with a voltage of DC 0/24 V.

A relay output with changeover contact is present in every device variant, regardless of the other specifications.

Customer-specific linearization

Thanks to individual linearization according to customer requirements, it is also possible to use sensor signals with special characteristics (e.g. PTC/NTC sensors while observing the resistance measuring range). Programming is carried out in the setup program either by means of a value table with up to 40 value pairs or by a formula (4th-order polynomial). The device supports 2 customer-specific linearizations.

Data recording

Measured values are recorded continuously with a sampling cycle of 125 ms. These measured values form the basis for generating reports and checking limit values. The transfer of measured values into the device’s working memory depends on the programmable storage cycle and storage value:

  • current value
  • average value
  • maximum value
  • minimum value
  • min./max. value

The data is stored by the screen recorder in groups, with a maximum of four groups assignable to each input.

Working memory (SRAM)

The data in the SRAM is regularly copied in blocks of 20 kilobytes each to the internal memory.

Internal memory (Flash)

When a memory block in the working memory is full, it is transferred to the internal memory, which has a maximum capacity of 1 GByte. Every write process is monitored in order to detect errors during data storage immediately. The device continuously monitors the capacity of the internal memory and activates a memory alarm signal when a configurable remaining capacity is reached, which can, for example, trigger the alarm relay.

The memory works according to the ring memory principle, so that older data is automatically overwritten by new data when the memory is full. For the history display in the screen recorder, data can be retrieved from the internal memory, whereby the history memory has a capacity of 8 MByte.

Data transfer to the PC

Data can be transferred from the screen recorder to a PC either via a USB storage stick or via one of the interfaces (USB device, Ethernet).

Data security

The data is encrypted and stored in a proprietary format, which ensures a high level of data security. In the event of a power supply interruption, the following conditions apply:

  • measured data in the working memory and the time are buffered by a lithium battery (service life of the lithium battery > 7 years)
  • if the lithium battery is discharged, the measured data in the working memory and the time are lost. During battery replacement, the data is buffered for approx. 2 minutes by a storage capacitor.
  • measured and configuration data in the internal memory are not lost.

The device with type addition 87 has tamper detection. Based on a digital device certificate, it can be proven that the register data in the device and during transfer to the data archive has not been manipulated.

Recording time

The maximum recording duration is influenced by various factors, above all by the selected storage cycle. If a group with 6 analog channels is activated in normal mode and the average values (not min./max. values) are stored, the values in the table apply. Entries in the event list can reduce the maximum recording duration.

Reports

The recording of reports (maximum, minimum, and average values) for each channel of a group can be carried out over defined periods. The configuration is performed individually for each group.

Batch log

The screen recorder enables the creation of a batch log for a system. The measured data, the start, the end, and the duration of the batch can be displayed together with a batch counter and freely definable texts both on the screen recorder and within the PCA3000 PC evaluation software. A barcode scanner can also be used to control the start and stop of the batch and to read in batch texts.

Recording GPS data

The device can receive and record GPS data in NMEA-0183 format via its serial interface. The data from the connected GPS receivers, such as positioning data, is entered cyclically into the event list (group-related) and can therefore be evaluated in conjunction with other recorded data.

Operating modes

The operating mode can be selected individually for each group. The storage cycle and storage value can be set separately for each operating mode. Up to 4 groups can be recorded with a storage cycle of 125 ms.

The operating modes have different priorities:

Event mode

Activation or deactivation of event mode is performed via a control signal such as a digital input, a group alarm, or a collective alarm. As long as the control signal is active, the device remains in event mode, which has the highest priority.

Time mode

Time mode is active daily within an adjustable time window, provided no event mode is active.

Normal mode

If the device is neither in event mode nor in time mode, normal mode is active.

Limit value monitoring

Thanks to adjustable limit value monitoring, up to 24 analog values can be monitored. If the limit value is exceeded or undershot, an alarm signal is generated that can be used for individual purposes, for example to switch the operating mode from normal to event mode. With the help of an alarm delay, short-term overshoots or undershoots can be masked so that no alarm signal is triggered.

It is also possible to suppress the alarm signal by means of a digital signal. Both the limit value and the switching differential can be adjusted during parameterization.

Counters/integrators

Six additional internal channels are available, which can be used as:

  • counter
  • integrator
  • operating hour counter
  • recording of a total flow quantity

Through digital inputs/outputs 1 and 2 (optionally 3), two high-speed counters with a frequency of up to 12.5 kHz can be implemented.

These optional inputs are also required for flow measurement in order to evaluate pulses from a flow sensor.

The counters are controlled by digital signals (counting pulses), while the integrators are operated by analog signals (the value is integrated according to the selected time base).

Operating hour counters record the period during which a digital signal is active.

The value of the counter/integrator is displayed numerically on the screen recorder with a maximum of 9 digits. In the event of an overflow, the counter starts again at 0.

Different recording periods can be set. A minimum and a maximum alarm can be configured for each counter/integrator.

Mathematics and logic module

The mathematics and logic module (6 channels each) is available as an option. With the mathematics function, various analog and Boolean input variables can be linked by means of a freely definable formula with a maximum length of 160 ASCII characters. The output variables are real values.

As an alternative to manual formula entry, predefined mathematical functions are also available, such as:

  • difference
  • ratio
  • humidity
  • moving average

The logic function allows the linking of different Boolean values using a logic formula that can be up to 600 ASCII characters long. The output variables are Boolean values.

The configuration of the mathematics and logic module is carried out exclusively via the setup program.

Structured Text

With the “Structured Text” option (type addition), the user is given the opportunity to develop a custom application. This application is created using the ST editor, which is part of the setup program, and uses the PLC programming language “Structured Text”.

Once completed, the application is transferred to the device and executed there continuously. Online debugger functions are available in the ST editor for troubleshooting and testing.

FDA-compliant data recording

With type addition 888, the screen recorder fully complies with FDA requirements according to 21CFR Part11. The PC software package (including PCS and PCAT) is required for user management and commissioning.

The device supports up to 50 users with specific rights. A user can provide a completed batch or the recorder data of a certain time period with their electronic signature. Even when logging off, a logged-in user can provide a signature, which then applies to the entire period during which they were logged in.

Visualization on the device

The screen recorder offers various display types for visualizing the measured data. The visualization screens after switching on the device can be selected in the configuration, as can the screen that appears when the home button is confirmed. Furthermore, the colors of the individual channels as well as the background color of the analog curves and digital tracks can be set.

Web server

The screen recorder is equipped with a web server function as standard.

The web server enables the user to display the following settings, process values, and messages using a web browser:

  • parameters of the application level
  • individual process screens
  • factory visualization
  • data of the recording function (including history)
  • alarm and event lists

The display depends on the web browser and the PC operating system used.

PC programs

The screen recorder is offered with two different basic type extensions:

Basic type 1:

  • includes the PC programs
    • Setup
    • PCC
    • PCA3000

Basic type 888:

  • in addition to the programs above, it also includes:
    • PCS
    • PCAT

See order details.

PCA communication software PCC

The PCA communication software PCC is a PC program developed for Windows operating systems (7/8/10 – 32/65 bit). It is used to read out the data of the screen recorder. The data can either be read out using a USB storage stick or via the interfaces (USB device, Ethernet).

The readout can be performed either manually or automatically, for example daily at 11:00 p.m.

PC evaluation software PCA3000

The PC evaluation software PCA3000 is a PC program for Windows operating systems (7/8/10 – 32/64 bit) used for the management, archiving, visualization, and evaluation of the data from the screen recorder.

  • The software recognizes the data from various configured devices and stores it automatically in an archive database. Only one identifier (supplementary description) must be assigned manually by the user.
  • Users can access specific data records at any time, which can be distinguished by the identifier. In addition, it is possible to limit the time periods to be evaluated.
  • Any analog and digital channels of a screen recorder, even from different groups, can subsequently be combined in PCA3000 into so-called PCA groups.
  • Each group is displayed in its own window, so that several groups can be shown and compared on the screen in parallel.
  • The export filter can be used to export the stored data for processing in other programs such as Excel.
  • The PC evaluation software PCA3000 is network-capable, which means that several users can independently access the data from the same archive file (*.177) in a network directory.
  • With the PCA3000 option “automatic printout”, in combination with the PCC software, batch data or reports can be printed automatically or made available as a PDF file in the network. The output forms used can be customized individually.

PC Security Manager PCS

The PCS software is used to manage access control for device users and is available exclusively to administrators. This software can only be used with devices that have type addition 888.

PC Audit Trail Manager PCAT

This software is used to document PC operating actions that lead to changes in data recording.

Advantages

  • intuitive touch operation
  • secure and tamper-protected data recording
  • flexible integration into existing systems
  • extensive visualization and evaluation options
  • suitable for applications requiring documentation

Dimensions

Height 10 mm
Length 14,4 cm
Width 14,4 cm

Weight

Weight 2,134 kg

Other attributes

Country of origin DE
Customs tariff number 90308400
Spannungsversorgung AC 110 bis 240 V + 10/-15% , 48 bis 63Hz
Technical data:

Galvanic isolation

Number

max. 6 (see connection plan)

A/D converter

Number

max. 6 (see connection plan)

A/D converter

24 bit Delta-Sigma

Sampling cycle

up to 6 channels: 125 ms

Speeds

-20 to +70 mV

 

2nd order digital filter; Filter constant adjustable from 0 to 100.0 s

Galvanic isolation

see "Galvanic isolation"

ITS

Measuring range

Designation

Type

Standard

ITS

Measuring range

Accuracy

Fe-CuNi

"L"

DIN 43710 (1985)

IPTS-68

IEC 60584-1:2013

-200 to +900 C

 0.1%

Fe-CuNi

"J"

DIN EN 60584-1:2014

ITS-90

-210 to +1200 °C

 0.1% from -100 °C

Cu-CuNi

"U"

DIN 43710 (1985)

IPTS-68

IEC 60584-1:2013

-200 to +600 °C

 0.1% from -100 °C

Cu-CuNi

"T"

DIN EN 60584-1:2014

ITS-90

IEC 60584-1:2013

-270 to +400 °C

 0.1 % from -150 °C

NiCr-Ni

"K"

DIN EN 60584-1:2014

ITS-90

IEC 60584-1:2013

-270 to +1300 °C

 0.1 % from -80 °C

NiCr-CuNi

"E"

DIN EN 60584-1:2014

ITS-90

IEC 60584-1:2013

-270 to +1000 °C

 0.1 % from -80 °C

NiCrSi-NiSi

"N"

DIN EN 60584-1:2014

ITS-90

IEC 60584-1:2013

-270 to +1300 °C

 0.1 % from -80 °C

Pt10Rh-Pt

"S"

DIN EN 60584-1:2014

ITS-90

IEC 60584-1:2013

-50 to +1768 °C

 0.15 % from 100 °C

Pt13Rh-Pt

"R"

DIN EN 60584-1:2014

ITS-90

IEC 60584-1:2013

-50 to +1768 °C

 0.15 % from 100 °C

Pt30Rh-Pt6Rh

"B"

DIN EN 60584-1:2014

ITS-90

IEC 60584-1:2013

0 to 1820 °C

 0.15 % from 600 °C

W5Re-W26Re

"C"

DIN EN 60584-1:2014

ITS-90

0 to 2315 °C

 0.1 % from 500 °C

W3Re-W25Re

"D"

ASTM E1751M-15

ITS-90

0 to 2315 °C

 0.1 % from 500 °C

W5Re-W20Re

"A1"

GOST R 8.585-2001

ITS-90

0 to 2500 °C

 0.1 % from 500 °C

Chromel-Copel®

"L"

GOST R 8.585-2001

ITS-90

-200 to +800 °C

 0.1% from -80°C

Chromel® Alumel®

"K"

 

ITS-90

-270 to +1372 °C

 0.1 % from -80 °C

PLII (Platinel® II)

 

ASTM E1751M-15

ITS-90

0 to 1395 °C

 0.1%

Comparison Point Accuracy (in- terner Pt100)

Ambient temperature influence

 100 ppm/K

Comparison agency

internal (Pt100) or external (constant) or external terminal with integrated junction (accessory)

externen Klemme (TC-Klemme, Accessories)b

Junction accuracy (internal Pt100)

 0,5 K bei Umgebungstemperatur 0 bis 40 °C

 1K

Comparison point temperature (external constant)

a  Accuracy refers to the measuring range.

b  The accuracy applies to the measuring range from -100 °C.

 

 

max. 10  per line for two-wire circuits

 

-30 to +85 °C (adjustable)

External

Typical  0.4 K at ambient temperature 23 °C

Basic measuring range

-20 to +70 mV

Measuring current

Pt50

DIN EN 60751:2009

IEC 60751:2008

ITS-90

-200 bis +850 °C

0,1 %

Designation

Standard

ITS

IEC 60751:2008

Measuring range

Accuracy

Measuring current

Pt50

DIN EN 60751:2009

ITS-90

IEC 60751:2008

-200 to +850 °C

 0.1%

500 A

Pt100

DIN EN 60751:2009

ITS-90

IEC 60751:2008

-200 to +850 °C

 0.1%

500 A

Pt500

DIN EN 60751:2009

ITS-90

-200 to +850 °C

 0.1%

50 A

Pt1000

DIN EN 60751:2009

ITS-90

-200 to +850 °C

 0.1%

50 A

Pt100

JIS C 1604:1981

IPTS-68

-200 to +649 °C

 0.1%

500 A

Pt50

GOST 6651-2009 A.2

ITS-90

-200 to +850 °C

 0.1%

500 A

Pt100

GOST 6651-2009 A.2

ITS-90

-200 to +850 °C

 0.1%

500 A

Cu50

GOST 6651-2009 A.3

ITS-90

-180 to +200 °C

 0.4%

500 A

Cu100

GOST 6651-2009 A.3

ITS-90

-180 to +200 °C

 0.4%

500 A

Ni100

 

IPTS-68

-60 to +250 °C

 0.2%

500 A

Ni100

GOST 6651-2009 A.5

max. 30  je Cable for three/four-wire circuits

a  Accuracy refers to the measuring range.

programmable within the limits in steps of 0.1 

 

ITS-90

-60 to +180 °C

 0.2%

500 A

Resistance Potentiometer/WFG

Connection type

2-/3-/4-wire

Ambient temperature influence

 50 ppm/K

Sensor Line Resistance

0 bis 4000 

max. 10  per line for two-wire circuits

max. 30  per line for three/four-wire circuits

500 A

50 A

 

Ambient temperature influence

Designation

Measuring range

Resistance Potentiometer/ WFG

Resistance/Poti

 

Accuracy

 

Zwei-/Drei-/Four-wire circuit

Measuring current

Resistance Potentiometer/WFG

0 to 4000 

 0.1%

50 A

Resistance/potentiometer

a Accuracy refers to the maximum measurement range. At small measuring spans, the linearization accuracy is reduced.

 

according to NAMUR recommendation NE 43 (only current input 4 to 20 mA)

 

0 to 400 

 0.1 %

500 A

Input resistance or load voltage

Ambient temperature influence

 100 ppm/K

Connection Type

>  Three-wire circuit

60 

Sensor Line Resistance

>  max. 10  per line for two- and three-wire circuits

programmable within the limits in steps of 0.1 

0,05 %

>  500 k

-1 bis +1 V

Designation

>  Measuring range

Input resistance or load voltage

Voltage

>  0 to 70 mV

 0.1%

500 k

0,1 %

0 to 10 V

500 k

0,1 %

-10 to +10 V

 

500 k

100 ppm/K

-1 to +1 V

Strom

 

 0.08%

0,5 mA

500 k

Strom

 

programmable within the limits in steps of 0.01 mV within the limits in steps of 0.01 mA arbitrarily programmable

0 to 1 V

 0.08%

a Accuracy refers to the maximum measurement range. At small measuring spans, the linearization accuracy is reduced.

Measuring Circuit Monitoring

is detected

 

500 k

Current

4 to 20 mA

 0.1%

 2V

is detected

0 to 20 mA

 0.1%a

 2V

is detected

Ambient temperature influence

 100 ppm/K

Smallest measuring span: voltage

5 mV

Measuring range start/end Voltage

programmable within the limits in steps of 0.01 mV within the limits in steps of 0.01 mA arbitrarily programmable

Measuring range under/exceeding

according to NAMUR recommendation NE 43 (only current input 4 to 20 mA)

is not recognized

is not recognized

Voltage 0 bis 70 mV

is detected

Transmitter

Antennae fracture

Short circuit

Reverse polarity

Thermocouple

is detected

is not recognized

is conditionally recognized

Resistance thermometer

is detected

is detected

is not recognized

Resistance Potentiometer/WFG

is detected

is not recognized

is not recognized

Resistance/potentiometer

is detected

is not recognized

is not recognized

Voltage 0 to 70 mV

is detected

is not recognized

is detected

Voltage 0 to 10 V

is not recognized

a  depending on the set characteristic curve

 

150 ppm/K

 

is not recognized

is detected

Voltage -10 to +10 V

Output Signal Load Resistance

 

is not recognized

>  500 

is not recognized

Output Signal Load Resistance

 

is not recognized

 450 

Voltage 0 to 1 V

is detected

is not recognized

is detected

 

DC 24 V +10/-15 %

 

Voltage -1 to +1 V

is detected

is not recognized

Pegel Sampling rate

Potential-free contact

 

is not recognized

125 ms (max. Zählfrequenz: 4 Hz)

RON:  1 k; ROFF:  50 k (Verwendung der Hilfsspannung 24 V)

Current 0 to 20 mA

Strom

 

is not recognized

max. 50 mA je Slot

DC 24 V +10/-15 %

 

is not recognized

is not recognized

Current 4 to 20 mA

is detected

is detected

Pegel Sampling rate

Potential-free contact

 

is detected

125 ms (max. Zählfrequenz: 4 Hz)

RON:  1 k; ROFF:  50 k (Verwendung der Hilfsspannung 24 V)

High-Speed-Entrance

Usable Inputs Function

Max. counting frequency

Duty cycle

Flow Measurement Accuracy

 

1, 2 (see connection plan)

counts each positive edge of the input signal 12.5 kHz

30 bis 70 % (High-Impuls  30 s, Low-Impuls  30 s)

0.5% of the measured value; Ambient temperature influence: 50 ppm/K

Exit

Output Strom

 

DC 0/24 V +10/-15 %; galvanically isolated

max. 40 mA per output, max. 100 mA in total (incl. current of the auxiliary power supply)

Number

Strom

 

max. 2 (see connection plan)

max. 100 mA (inkl. Strom der Digitalausgänge)

3 A at AC 230 V or DC 30 V, resistive load

 

Voltage,

DC 0 to 10 V

Current

Output Signal Load Resistance

 

DC 0(4) to 20 mA

 450 

 

1 (rear) Micro-B (socket)

 

Accuracy

Number

Plug Type Baudrate Data format

Protocol Deployment

 

Externe Inputs

 

0,5 %

4800, 9600, 19200, 38400, 115200

8/1n, 8/1e, 8/1o

Modbus RTU als Master oder Slave, Barcode-Scanner, NMEA 0183

Communication with Modbus Master/Slave, Connection of a barcode scanner or a GPS

Recipient

above Modbus-Master/Slave-Functionality: 24 analog and 24 digital inputs, 10 batch texts, 4 event texts

Ambient temperature influence

Number of plug type

Transmission rate Protocol

Use

Externe Eingänge Max. Length

 

150 ppm/K

10 Mbit/s, 100 Mbit/s

IPv4; TCP, UDP; DHCP, DNS, HTTP, SMTP, SNTP, Modbus-TCP

Communication with PC (setup program, data archiving), Webserver), E-Mail-Server, SNTP-

Server und Modbus-Master/Slave

via Modbus master/slave functionality: 24 analog and 24 digital inputs, 10 batch texts,

4 Event Texts

 

100 m

PROFINET IO Device

Number of plug type Transmission rate

Conformity class Netzlastklasse Protocol

Use

 

 

 

Max. cable length

 

1 (alternative to Ethernet interface)

2 x RJ45 (Buchse), integrierter Switch 100 Mbit/s

B (CC-B)

III (Netload Class III)

DCP, LLDP, VLAN Priority, PTCP

Communication with PROFINET-IO-Controller; in addition, the Ethernet standard services are supported

100 m

USB-Host

Number of plug type

Standard Insert

Max. Load Current

 

Number

USB 2.0 (Hi-Speed)

Exclusively for connecting a USB memory stick (FAT16/FAT32; see accessories) 100 mA

max. 12 (see connection plan)

Number of plug type

Standard Insert

Max. cable length

 

Input

Level Sampling Rate

Floating Contact

 

after waiting time or by control signal

 

logic "0":  3.5 V; logic "1":  10 V

Auxiliary Power Supply VoltageCurrent

DC 24 V +10/-15 %

14,5 cm (5,7“)

Resolution

Number

max. 12 (see connection plan)

Input or output

individually configurable as input or output

Input

logic "0":  3.5 V; logic "1":  10 V

High-Speed

1, 2 (see connection diagram)

Output

a TFT color screens may have pixel defects due to technology and production. Up to four pixel errors are considered permissible for this screen recorder and do not entitle you to assert warranty claims.

 

10 mm

 

DC 0/24 V +10/-15 %; galvanically isolated

Auxiliary Power Supply Voltage

Current

DC 24 V +10/-15 %

according to DIN EN 61010-1

Overvoltage category II up to 300 V mains voltage, degree of contamination 2

Class

Number

1 (see connection plan)

 

3 A at AC 230 V or DC 30 V, resistive load

45 VA

AC/DC 20 bis 30 V

30 VA

RS232/RS485

1 (switchable between RS232 and RS485) SUB-D 9-pin (socket)

Ethernet

1 (alternative to the PROFINET interface) RJ45 (socket)

PROFINET IO Device Number of connector type Transmission rate

1 (alternative to Ethernet interface)

USB Host

1 (front, with cover) A (socket)

USB Device

Number of Plug Type Standard Use

Max. Cable Length

2 × stranded wire with twin ferrule with plastic collar

Stripping length

 

1 (rear) Micro-B (socket)

 

USB 2.0 (Hi-Speed)

for connection to a PC (Setup program, PCC/PCA3000) 5 m

 

10 mm

Conductor cross-section on terminals 4, 14 und 15

 

Wire or stranded wire

Kind2)

TFT color screen / touch screen (resistive)

 

14.5 cm (5.7")

Resolution2)

640 × 480 pixels (VGA)

Number of colours

65536

 

60 Hz (typ.)

Brightness adjustment2)

Adjustable on the device

 

after waiting time or by control signal

without plastic collar: min. 0,25 mm2, max. 1,5 mm2 (with terminal cover: max. 0,5 mm2)

 

with plastic collar: min. 0,25 mm2, max. 0,5 mm2

Stripping length

Power supply

AC 110 to 240 V +10/-15 %, 48 to 63 Hz or

 

according to DIN EN 61010-1

 

I with internal separation to SELV

Power consumption2)

without ferrule

 

 45 VA

AC/DC 20 to 30 V2, max. 1,5 mm2 (mit Klemmenabdeckung: max. 0,5 mm2)

 

Backup2, max. 0,75 mm2 (mit Klemmenabdeckung: max. 0,5 mm2)

internal flash memory

Data buffering

 

according to DIN EN 61326-1

 

battery (lifespan  7 years); Additional storage capacitor for buffering during battery change (buffer time approx. 2 minutes)

Operation

 

Clock

-20 bis +50 °Ca; in Verbindung mit Typenzusatz 970: 0 bis 40 °C

battery-backed real-time clock

Electrical connection

Rear via plug-in spring-loaded clamps

Storage

Operation

Conductor cross-section at terminal 5

Wire or stranded wire without ferrule

Stranded wire with ferrule

min. 0.2 mm2, max. 2.5 mm2,

min. 0.2 mm2, max. 2.5 mm2, min

. 0.5 mm2, max. 1.5 mm2 (both strands with the same cross-section)

Conductor cross-section at terminals 4, 14 and 15

according to class 1M2

to class 2M2 to Klasse 3M3

Electromagnetic compatibility (EMV) Emission

Stability

Wire or stranded wire

Klasse A - nur für den Industrial Use - Industrial Requirement

a At temperatures below 0 °C, the build-up of the screen content slows down.

 

max. 1.65 kg (without clamp cover)

 

min. 0.2 mm2, max. 2.5 mm2 (with terminal cover: max. 1.5 mm2

without ferrule

Cabinet front

Stranded wire with ferrule

min. 0.25 mm2, max. 2.5 mm2 (with terminal cover: max. 1.5 mm2

Stripping length

10 mm

Conductor cross-section at terminals 6 to 13

Panel cutout

Wire or stranded wire

min. 0.14 mm2, max. 1.5 mm2 (with terminal cover: max. 0.5 mm2

without ferrule

Housing Mounting

Stranded wire with ferrule

without plastic collar: min. 0.25 mm

any, taking into account the viewing angle of the screen, horizontal ±50°, vertical ±30°

with plastic collar: min. 0.25 mm

Stripping length

in Verbindung mit Typenzusatz 970: IP20 when the carrying case is open, IP20D with the carrying case closed

9 mm

Conductor cross-section at TC terminal (attachment

all versions of the built-in appliance; not in combination with type suffix 970

 

Mark

listen)

Certificate/Test Number

Wire or stranded wire

min. 0.20 mm2, max. 1.5 mm2 (with terminal cover: max. 0.5 mm2

without ferrule

Underwriters Laboratories

Stranded wire with ferrule

without plastic collar: min. 0.25 mm

2

, max. 1.5 mm2 (with clamp cover: max. 0.5 mm

all versions of the built-in appliance; not in combination with type suffix 970