Skip to main content Skip to search Skip to main navigation

Water treatment system for outpatient clinics in standard design

Product number: 896528

Product information "Water treatment system for outpatient clinics in standard design"

The modular water treatment system was specially developed for the outpatient care sector. While the overall geometry, the system can be adapted to the different degrees of water hardness in Germany, the the quantities required in different outpatient centers, as well as to the initial water quality, including any treatment treatment steps on the part of the suppliers. The modularity offers the decisive advantage that the overall concept can be adapted to the respective water type or composition as well as the supplier's treatment processes.

Principle
Due to its modular design, the water treatment system can be adapted to the different conditions in outpatient care. to the different conditions in the outpatient care sector. be adapted. These include different degrees of water hardness, quantities required in outpatient centers, the initial water quality and the treatment steps. Optimum water treatment is relevant for the reliable availability of instruments for for operations. It also goes hand in hand with the protection of and equipment technology. Furthermore, any damage to the damage to the instruments or equipment is always directly directly related to the issue of patient safety. For the pre-filtration, a softening system and a reverse osmosis system with a 100 liter permeate a reverse osmosis system with a 100 liter permeate tank including surge tank and sterile filter as well as permanent conductivity and silicate silicate monitoring using a Testomat® 808 SiO2 on the blending bed and recirculation system with integrated UV system and pyrogen filter

Wastewater discharge via brine lifting unit
As an optional component, the treatment plant can be extended by an integrated wastewater lifting unit. integrated wastewater lifting unit, which discharges the generated and and collected wastewater into the sewer system. The main wastewater volume flows are the wastewater from the regeneration of the of the softening plant and the concentrate from the reverse osmosis should be mentioned. The discontinuously occurring wastewater flows from the wastewater flows from the silicate meter, the system separator and the rinsing water that is produced when the input filters (in particular

Cut-off via system separator
To protect the drinking water network from contamination by treated water or changes in the natural composition of the water, the system separator is also used. water or changes in the natural composition of the of the drinking water fed into the system due to the technical treatment the installation of a system separator is mandatory. The system has an integrated system separator (type BA), which is located directly behind the Aqua-Stop of the water connection.

Rittal enclosure systems
The system components are installed in two Rittal enclosures. Rittal is a leading manufacturer of enclosure systems and offers a wide range of range of solutions for the secure storage and protection of electronic electronic components and devices. Rittal enclosure systems are available in various sizes, designs and configurations and configurations and are suitable for various application areas such as IT infrastructure industrial automation, power distribution and telecommunications.
Rittal enclosure systems are characterized by high quality, functionality and flexibility. and flexibility. Rittal enclosures are made from high-quality materials and offer a robust construction that provides reliable protection reliable protection for the equipment inside. They are protected against dust, dirt, moisture, vibrations and other environmental environmental influences. Rittal enclosure systems are modular which means that they can be adapted to the specific requirements and the available space. They offer a variety of options for mounting accessories such as shelves, cable management, climate control units and power distribution units. The enclosure systems from Rittal offer various security features such as lockable doors, security locks and access control systems, to prevent unauthorized access to the equipment and ensure data security. data security. For the installation of the modular water treatment plant from HeylNeomeris only requires a minimum footprint of footprint of 1.60m x 1m is required. It consists of 2 cabinets that are 80cm wide and 60cm deep. It is possible to work with double-wing doors and thus, due to the depth of 60cm and a double of 60cm and a double wing door with a dimension of 40cm, this results in a
The cabinets used are made from sturdy sheet steel modules and have a high-quality surface coating. and have a high-quality surface coating.

Standard equipment of the system

Testomat® 808 SiO2 silicate measuring device
A Testomat® 808 SiO2 silicate measuring device is used for continuous silicate monitoring. SiO2 silicate is used. The Testomat®808 SiO2 is a measuring device, which is used to determine the silicate content in water. The measuring principle of the Testomat®808 SiO2 is based on the so-called molybdenum blue method. The silicate in the water reacts with a reagent solution containing molybdenum. This reaction produces a blue color whose intensity is proportional to the silicate content. The measuring device records the color intensity using an optical sensor and converts it into a measured value that represents the silicate content of the water. of the water. The Testomat®808 SiO2 is housed in a compact casing which contains a user interface, display and control elements as well as and connections for water samples and drainage.
The use of Testomat 808®SiO2 ensures reliable compliance with the requirements of the DGSV and AKSV. compliance with the limit value for SiO2 recommended by the DGSV and AKI of of 0.4 mg/l is ensured.
If the limit value is exceeded, it is possible to report this to the optionally available to the optionally available NeoTecMaster® or directly to an optical warning directly to an optical warning element. Continuous monitoring of the silicate content is required, deposits and any resulting damage to equipment and instruments. damage to device technology and instruments effectively.
By using the Testomat®808 SiO2, companies can continuously monitor the silicate continuously monitor the silicate content and, if necessary, take appropriate measures to prevent deposits.
Continuously monitor the silicate content and take appropriate measures if necessary to prevent deposits.

Optional components of the system:
  • UV Disinfection Mini
  • Pyrogen filter
  • Lifting system
  • NeoTecMaster® 5 inch with housing
  • Viewing window
  • Interior lighting
  • Aqua-Stop (solenoid valve shut-off)
  • Collection trays

Dimensions

Height 1.800 cm
Length 1.600 cm
Width 80 cm

Weight

Weight 100 kg

Other attributes